4. Connect a jumper wire (reference gray) between the negative (–) terminal
on battery
C
to the positive (+) terminal on battery
B
.
IMPORTANT: The jumper wire should be the same wire gauge as the
negative (–) and positive (+) power cables.
5. Connect a jumper wire (reference gray) between the negative (–) terminal
on battery
B
to the positive (+) terminal on battery
A
.
6. Connect the trolling motor negative (–) lead to the negative (–) terminal on
battery
A
.
7. Starting with the positive (+) lead, reconnect the battery cables to the
engine starting battery.
36-volt battery connection
a -
Power cables to trolling motor
b -
Manual reset circuit breaker
c -
Jumper wire (not supplied)
d -
Negative (–) battery terminal
IMPORTANT: Do not connect a common ground bond cable between 36‑volt
and 12‑volt electrical circuits.
RED
BLK
37825
GRY
c
Battery B
Battery C
Battery A
GRY
c
a
b
c
d