Section 5 - Storage
Page 58
90-8M0128975
eng
JUNE 2017
IMPORTANT: If water does not drain from the seawater pump housing when both green indicators are extended, remove
the blue drain plugs on the seawater pump housing.
a -
Seawater pump housing water drain
b -
Blue drain plugs
11. There are specific blue drain plugs that must be removed because the engine angle is greater than the air actuated drain
system allows for proper draining of the system. Remove the blue drain plugs shown in the following illustrations.
Port side
a -
Standard cooling (two blue drain plugs)
Starboard side
a -
Standard cooling (two blue drain plugs)
12. Allow the system to drain for a minimum of ten minutes. Pump air as necessary to keep the green indicators extended.
13. Crank the engine over slightly with the starter motor to purge any water trapped in the seawater pump. Do not allow the
engine to start.
IMPORTANT: This engine has an automatic start function controlled by the PCM. The start function can be terminated by
turning the key to the OFF position.
14. Do not allow the engine to start.
15. After the water has drained from the engine, install the blue plugs on the distribution housing and seawater pump if they
were removed and tighten securely.
16. Push the locking lever down on the air pump and remove the pump from the air actuator assembly. Install the cap on the
fitting.
17. Install the blue plug on the engine block crossover and tighten securely.
a