MAINTENANCE
SECTION 5
Page 84
CMD-4081877 / 90-865861040 MARCH 2004
00000 new
Flushing The Seawater System
NOTE:
The closed cooling section of the cooling system that contains coolant does not need
to be flushed. Coolant is changed at specified intervals. Refer to Maintenance Schedules.
Flushing the seawater system with fresh water is needed only for salty, brackish, mineral
laden or polluted water applications to avoid silt or salt buildup. For best results flushing is
recommended after each outing. The seawater cooling system must be flushed after each
operation in saltwater and prior to storage.
CAUTION
When flushing the seawater cooling system, close the seacock, if so equipped. If
the boat is not equipped with a seacock, remove and plug seawater inlet hose to
prevent a siphoning action that may occur, allowing seawater to flow from the drain
holes or removed hoses.
1.
If flushing the engine with the boat in the water:
close the seacock, if equipped, or
disconnect and plug the seawater inlet hose.
70355
70062
a
b
c
a -
Seacock
b -
Seawater inlet hose
c -
Plug
WARNING
When flushing, be certain the area around propeller is clear, and no one is standing
nearby. To avoid possible injury, remove the propeller.
2.
If flushing the engine with the boat out of the water
: remove the propeller. Refer to
boat manufacturers’ instructions.
Содержание 2.8 EI 200
Страница 1: ...2004 Mercury Marine 2 8 EI 200 Diesel Inboard Models CMD 4081877 90 865861040 304...
Страница 28: ...GETTING TO KNOW YOUR POWER PACKAGE SECTION 2 Page 20 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 56: ...SPECIFICATIONS SECTION 4 Page 48 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 96: ...MAINTENANCE SECTION 5 Page 88 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 104: ...STORAGE AND RECOMMISSIONING SECTION 6 Page 96 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 118: ...75308 CUSTOMER ASSISTANCE INFORMATION SECTION 8 Page 110 CMD 4081877 90 865861040 MARCH 2004 00000 was CD851...