MAINTENANCE
SECTION 5
Page 83
CMD-4081877 / 90-865861040 MARCH 2004
00000 – was
Cleaning The Seawater Strainer, If Equipped
1. Visually inspect seawater strainer through glass top.
CAUTION
While cleaning the seawater strainer, seawater can flow into the engine or engine
compartment causing damage to the engine or boat. Water inlet must be closed
before cleaning the seawater strainer.
CAUTION
Do not overtighten the cover screws or the cover will warp and leak.
2. With the engine off, close the seacock (if equipped) or remove and plug the seawater
inlet hose if no seacock exists.
3. Remove the screws, washers, and cover.
4. Remove the strainer, drain plug and washer.
5. Clean all debris from the strainer housing; flush both the strainer and housing with clean
water.
6. Check the gasket and replace it when necessary (if it leaks).
7. Reinstall the strainer, drain plug and washer.
8. Reattach the cover with the screws and washers.
9. Open the seacock (if equipped) or remove the plug and reconnect the seawater inlet
hose.
10. After starting engine, check for leaks and/or air in system, which would indicate an
external leak.
78157
a
b
c
d
e
f
Typical
a -
Screws and washers
b -
Cover, with glass
c -
Strainer
d -
Housing
e -
Drain plug and sealing washer gasket
Содержание 2.8 EI 200
Страница 1: ...2004 Mercury Marine 2 8 EI 200 Diesel Inboard Models CMD 4081877 90 865861040 304...
Страница 28: ...GETTING TO KNOW YOUR POWER PACKAGE SECTION 2 Page 20 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 56: ...SPECIFICATIONS SECTION 4 Page 48 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 96: ...MAINTENANCE SECTION 5 Page 88 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 104: ...STORAGE AND RECOMMISSIONING SECTION 6 Page 96 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Страница 118: ...75308 CUSTOMER ASSISTANCE INFORMATION SECTION 8 Page 110 CMD 4081877 90 865861040 MARCH 2004 00000 was CD851...