Menvier Security TS510 Скачать руководство пользователя страница 9

User Functions

SETTING THE SYSTEM

1.

Enter your passcode - the (UNSET) light will

flash.

2.

Wait 5 secs until the (FUNCTION) light goes out

and the exit tone will start. Leave via the

designated exit route, closing the door.

3.

The system is set when the exit tone stops and

the two tone confirmation tone is heard.

NOTES:
A)

If the exit tone continues and (if fitted) the

strobe light on the bell box is flashing the

system has not set and you must re-enter the

premises, re-enter the passcode and start

again.

B)

If you change your mind whilst setting the

panel and wish to unset it again press (0) (END)

or wait until the (FUNCTION) light goes out and

re-enter your passcode.

PART SET THE SYSTEM

1.

Enter your passcode - the (UNSET) light will flash

2.

Press [7] (OMIT A) OR [9] (OMIT B) as appropriate

- the zones omitted will flash.

3.

After a pause the exit tone will start.

4.

The system is part set when the exit tone stops.

The following options may be accessed by entering

the USER 1 passcode IN REVERSE ORDER (eg for

passcode 5678 - enter 8765) followed within 5

seconds by the function key you require.  These

facilities are not available to User 2 who is restricted

to Set, Part-set and Unset activities.
NOTE: TS500 enter code in forwards and not in

reverse for following functions

Testing Sounders

1.

Enter User 1 passcode

IN REVERSE

and the

tone will start - press [1] (BELL TEST) immediately.

2.

All panel lights illuminate followed by 5 second

sequential activations of internal sounders,

external sounders and strobe (if fitted).

3.

Panel returns to [UNSET] condition on

completion of testing.

Testing Detectors

1.

Enter User 1 passcode

IN REVERSE

and the

tone will start - press [2] (WALK TEST)

immediately.

2.

Activate selected detectors or door contacts

and smoke detectors if fitted.

3.

Zone light illuminates and two tone sounder is

heard for each device activated.

4.

Press [0] (END) to complete test - [UNSET] will

illuminate.

Change User 1 Passcode

1.

Enter User 1 passcode

IN REVERSE

and the

tone will start - press [4] (USER 1) immediately

2.

Four zone lights illuminate and 15 seconds is

allowed to commence entry of the new code.

3.

Enter new passcode extinguishing the four

zone lights.

4.

Four zone lights illuminate again.

5.

Repeat new passcode (as confirmation).

6.

Two tone confirmation sound heard - new

passcode accepted - [UNSET] will illuminate.

Change User 2 Passcode

1.

Enter User 1 passcode

IN REVERSE

and the

tone will start - press [6] (USER 2) immediately.

2.

Four zone lights illuminate and 15 seconds is

allowed to commence entry of the new code.

3.

Enter new User 2 passcode extinguishing the

four zone lights.

4.

Four zone lights illuminate again.

5.

Repeat new User 2 passcode (as

confirmation).

6.

Two tone confirmation sound heard - new User

passcode accepted - [UNSET] will illuminate.

Selecting Chime

With the system unset you may wish to be alerted

when door contacts or detectors are activated.  You

can set nominated devices to “CHIME”:

1.

Enter User 1 passcode

IN REVERSE

and the

tone will start - press

[5

] (CHIME) immediately.

2.

Any zones set to chime will illuminate.

3.

To add or delete chime zones press the

relevant zone number within 15 seconds.

4.

Zone lights indicate status (LIT=CHIME,

UNLIT=NORMAL).

5

.

When satisfied press [0] (END).

6.

Two tone confirmation sound heard - [UNSET]

will illuminate.

Change Part Set Areas

If you wish to re-arrange your part-set areas:

1.

Enter User 1 passcode

IN REVERSE

and the

tone will start - press

[7]

(OMIT A) OR

[9]

(OMIT B)

immediately as required.

2.

Zone lights flashing indicate

those zones

omitted

3

.

To add or delete omit zones press the relevant

zone number within 15 seconds.

4.

Zone lights indicate status

496525 Issue A

9 of 10

TS510 & TS500

TS510 & TS500

Содержание TS510

Страница 1: ...TS510 TS500 Installation User Guide Compatible Equipment TS510 REM Remote Keypad 9040 Loudspeaker DC54 58 Digital Communicator SD1 Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 ...

Страница 2: ...eypad 1 only and Keyswitch Plug on digicom DC3 or plug on interface TS500 510 IF for connection to digicoms DC3 Redcare STU Paknet etc Conforms to BS4737 Part 1 1986 Input Voltage 240V 10 50Hz Panel DC Current 30mA 100mA in alarm REM DC Current 10mA Current Available 750mA MAX AUX Bell Current Battery Capacity 12V 2 6 3 2Ahr batteries not supplied Dimensions W x H x D 260 x 213 x 85mm Weight Panel...

Страница 3: ...r sounders 3 Insulation testing should only be carried out when the cable under test is disconnected from electronic circuitry at both ends NOTE TS500 Aux TMP Main Bell TMP OP1 WLK TST OP2 SW 12V 496525 Issue A 3 of 10 TS510 TS500 TS510 TS500 ALARM TAMPER Normally Closed P A Button Normally Open Keyswitch Normally Open Pushbutton Alarm Tamper ALARM TAMPER 0V 12V MOVEMENT DETECTOR WIRED END OF LINE...

Страница 4: ...d the cover is securely clipped to the base Finally re connect the mains supply and test the operation of the remote keypad 5 If more than 1 remote keypad is to be used connections may be in a star or daisy chain configuration NOTE TS500 only compatible with TS500 REM NOTE TS500 only link LKI If open the remote keypad will have full functions if closed you can only use remote keypad to set part se...

Страница 5: ...10 TS510 TS500 TO REMOTE KEYPAD TO DC 3 DC 3 CHANNELS 1 FIRE 2 PA 3 ALARM 4 SET UNSET 5 ENGINEER ON SITE DIGI INTERFACE REMOTE INTERFACE SPARE PINS OR SHORTING LINK Fig 5 DC3 and TS500 REM Connections TO REMOTE KEYPAD REMOTE INTERFACE DIGI INTERFACE TERMINAL BLOCKS top to bottom LINE FAULT ve applied during line fault 0V 12V 8 SOUNDER ON 7 BELL ON 6 PART SET 5 ENGINEER ON SITE 4 SET UNSET 3 ALARM ...

Страница 6: ...W F EXIT input is full set keyswitch Set inhibited on mains fail OPTIONS 2 NOT APPLICABLE TO TS500 Exit Terminator chimes Exit Terminator disabled Timed exit set Auto rearm User reset Engineer s Reset 1 Enter Engineer code default 1234 The CALL ENGR LED will illuminate You are now in Engineer mode 2 Press 0 twice to return to unset Loading Defaults 1 Power down panel mains and battery 2 Wire in a ...

Страница 7: ... the zone LED on off Once the setting is correct press O END and listen for the confirmation tone LED 1 2 3 4 5 ON FOR ON OFF ON OFF ON OFF ON OFF ON OFF NO DEFAULT ZONES EXIT TIME Press 4 and 3 zone LED s will light indicating that a 3 digit exit time in secs is required Once complete the confirmation tone will be heard e g for 30 secs enter 030 EXIT TIME S DEFAULT 030 SECS ENTRY TIME Press 5 and...

Страница 8: ...NS FAILURE RISING ENTRY AND EXIT TONES SET ALLOWS WITH LINE FAULT NOT USED NOT USED OFF FOR SET DISALLOWED WITH MAINS FAILURE CONTINUOUS ENTRY AND EXIT TONES SET DISALLOWED WITH LINE FAULT NOT USED NOT USED ENGINEER CODE Press 7 and 4 zone LEDs will light indicating that a 4 digit engineer code is required Once entered re enter the code for confirmation and listen for the confirmation tone ENGR CO...

Страница 9: ...tacts and smoke detectors if fitted 3 Zone light illuminates and two tone sounder is heard for each device activated 4 Press 0 END to complete test UNSET will illuminate Change User 1 Passcode 1 Enter User 1 passcode IN REVERSE and the tone will start press 4 USER 1 immediately 2 Four zone lights illuminate and 15 seconds is allowed to commence entry of the new code 3 Enter new passcode extinguish...

Страница 10: ...to stop sounder 2 Check detection devices in zone indicated 3 If you can correct the fault do so and then enter your passcode and press 0 END System returns to UNSET 4 If fault cannot be remedied call your engineer PA illuminated 1 Manually reset Panic button with the key provided 2 Enter your passcode PA indicator on 3 Enter your passcode and press 0 END POWER light out This will occur if there i...

Отзывы: