Overview
Introduction
This installation manual is intended to help you install
the TS510 as quickly and easily as possible. It is
therefore very important to read the manual
thoroughly
before
starting any work. This is particularly
significant if it is your first TS510 installation.
The TS500 was the predecessor to the TS510. The
differences between the two panels are noted
throughout this guide.
Specification
5 Programmable Zones with individual Tamper circuits,
plus fixed PA and Exit Terminator Outputs for Bell,
Strobe and 16 Ohm Loudspeaker
Optional Remote Keypad (1 only) and Keyswitch
Plug-on digicom DC3 or plug-on interface
(TS500/510.IF) for connection to digicoms DC3,
Redcare STU, Paknet etc.
Conforms to BS4737: Part 1: 1986
Input Voltage:
240V + 10% 50Hz
Panel DC Current:
30mA, 100mA in alarm
REM DC Current:
10mA
Current Available:
750mA MAX (AUX + Bell
Current)
Battery Capacity:
12V, 2.6/3.2Ahr (batteries not
supplied)
Dimensions:
W x H x D 260 x 213 x 85mm
Weight Panel
1.5Kg
Remote Keypad
125 x 127 x 32mm
Weight Keypad
200g
Environment:
0° - 55
°
C (INDOORS)
TS510 & TS500
2 of 10
496525 Issue A
TS510 & TS500
1 2 3
4 5 6
7 8 9
0
PCB CLIP
ACCESS TO TAMPER
SPACE
FOR
BATTERY
NOVRAM
BELL FUSE F2 (1A)
AUX FUSE B1 (1A)
BATTERY REVERSAL INDICATOR
VOLUME CONTROL
1
2
3
4
5
POWER TAMPER
CALL
ENGR
PA
EXIT
UNSET
FUNCTION
Figure 1 - TS510 Assembly Layout