Defaults
Key Functions
TS510 & TS500
TS510 & TS500
6 of 10
496525 Issue A
ENGINEER CODE
= 1234
OPTIONS 1: (NOT APPLICABLE TO TS500)
MASTER USER CODE
= 5678
Bell output is SAB
LAST EXIT ZONE
= ZONE 1
Alarm cleared on reset
ACCESS ZONE
= ZONE 2
Audible P.A.
EXIT TIME
= 30 secs.
P.A. audible in line fault
ENTRY TIME
= 30 secs.
Fire output signals during Full Set only
BELL DURATION
= 20 min.
Output 1 is WALK TEST
BELL DELAY
= 0 min.
Output 2 is SW12V
REMOTE RESET REF
= 004
KEY SW/F.EXIT input is
full set keyswitch Set inhibited on mains fail
OPTIONS 2: (NOT APPLICABLE TO TS500)
Exit Terminator chimes
Exit Terminator disabled
Timed exit set
Auto rearm
User reset
Engineer’s Reset
1.
Enter Engineer code default 1234. The CALL ENGR
LED will illuminate. You are now in Engineer mode.
2.
Press
0
twice to return to unset.
Loading Defaults
1.
Power down panel mains and battery.
2.
Wire in a small piece of cable across two terminals
for exit terminator.
3.
Power up battery and mains.
4.
Enter 1234 and remove link.
5.
The panel is now back to Factory Default
Programming.
Bell Test/Walk Test
Please refer to user function numbers 1 & 2
respectively.