13. Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in
ignition or if flame is "lifting off" burner, turn off burner and carefully check for proper installation of
logs/coals, vent system and proper pilot flame impingement on burner and thermopile. Logs or coals must not
block pilot flame or main burner flame. Vent system must be leak proof.
DO NOT PROCEED WITH OPERATION UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS!
14. To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature (see FIGURE 11: Gas
Valve).
Heat output can be reduced to 22,400 BTUH using the Hi-Lo Control. NEVER "over fire" by increasing
BTUH above nameplate specifications. NEVER turn down (reduce) pilot flame below the minimum 325
millivolts.
15. To reduce the flame and heat down to 6500 BTUH., use the rocker switch (see step 7) to turn off rear burner.
NOTE: The rear burner is controlled by a 9 Volt DC solenoid valve. One 9 Volt cell battery (located
behind the control panel) provides power for this unique feature. Replace with a new high quality 9 Volt
battery annually.
16. Open windows for first two hours of operation.
NOTICE: Initial heater start-up will cause some NON TOXIC "off gassing" of adhesives, gasket binders, paint and other
materials. Most nuisance odors will be eliminated after the first two hours of operation; however, slight amounts may be present
during first 24 hours of initial operation
. To eliminate all nuisance odors, continuously operate this fireplace on
the HIGH setting for 8 to 12 hours.
SHUT DOWN PROCEDURE:
1. Turn Remote Control or Thermostat to "OFF". Pilot will remain lit for return to normal service.
2. For complete shutdown turn Gas Cock Dial to "OFF".
WARNING:
Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper operation after servicing.