85-03-01115
DXV35 TIMBERFIRE
Page
75
. U
se Kel Kem “polish plus" (part # 65
-06-00455) or comparable product to clean glass interior surface. Do not use oven
cleaner or abrasive cleaners to clean glass.
6.3
REQUIRED ANNUAL MAINTENANCE
See
Chapter 5.7 What maintenance is required?
In addi
tion to the “Required Periodic Inspections”, the following procedures m
ust be performed each year by
a qualified installer, service agency or the gas supplier . Any adjustments to burner, pilot or logs must be
done by a qualified installer, service agency, or the gas supplier.
Clean all lint and dust build-up around the control and blowers. Inspect the condition of any wiring under the burner for melting
or damage. Clean thermocouple and thermopile tips using emery cloth. Vacuum all burner ports and pilot assembly.
Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs. Be sure the burner ports are
"open". Clean the pilot and under side of the logs for any Carbon deposits.
NOTE: Logs should be visually checked for Carbon "build -up". If heavy carbon deposits are visible on logs,
unit should be turned off and a qualified installer, service agency, or the gas supplier should be contacted .
Be sure logs are re-installed per instructions.
Check glass gasket seal. Visually inspect glass gasket, especially at the corners of the glass piece. Glass gasket is installed as a 4-
piece assembly. Check joints between the gasket pieces at the corners. They should butt against each other to create a seal. Gaps
between gasket pieces can cause exhaust leaks and lead to acrid smell concerns.
Содержание DXV-60
Страница 14: ...85 03 01115 DXV35 TIMBERFIRE Page 14 Figure 3 10 Figure 3 9...
Страница 36: ...85 03 01115 DXV35 TIMBERFIRE Page 36 Approved Vent Systems Figure 3 29 Approved Vent Systems...
Страница 62: ...85 03 01115 DXV35 TIMBERFIRE Page 62...
Страница 63: ...85 03 01115 DXV35 TIMBERFIRE Page 63...
Страница 64: ...85 03 01115 DXV35 TIMBERFIRE Page 64...
Страница 85: ......
Страница 86: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...