DXV35 TIMBERFIRE
Page
55
DXV35 TIMBERFIRE Master Venting Chart
Note: This chart is applicable to both natural gas and LP installations.
❑
12
” minimum vertical pipe run required to be
connected directly to
this fireplace’s flue starter
collar.
❑
Maximum horizontal run allowed with the
minimum 12
” vertical run is
6
”.
❑
Maximum vertical run allowed is 55
’.
❑
Maximum vent system length allowed is 55
’.
❑
1
2’ maximum horizontal run allowed with a
minimum 4 to 25
’ starter section. Three 90
°
elbows
may be installed anywhere within the 1
2’
horizontal run. If the starter vertical section is less
than 4’, use the chart and reduce 3’ for every 90
°
elbow installed after the first 90
°
elbow.
High Altitude Installation Information
Prior to installing at altitudes higher than 7500,
please contact the Mendota technical service
department for specific venting requirements and
venting restrictions.
Figure 4-11 MASTER VENT CHART