85-03-01115
DXV35 TIMBERFIRE
Page
17
Fireplace Features
EXTERNAL DIMENSIONS
: 36-1/4 Wide X 31-7/16
” High X 15
-5/8
” Deep
MINIMUM FRAMING DIMENSIONS
: 36-1/4
” WIDE x 31
-
7/16” HIGH X 15
-
1/8” DEEP
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 28-
3/8” X 16
-
1/16”
.
MANTEL ALLOWANCE
: 8” Deep Mantel at 1
4
” Above Top Convection Opening
(41” up from base of Unit)
VENT SYSTEM ALLOWANCE
: Top Vent Only.
12”
Vertical Minimum
with 6” max horizontal
. 55 feet Vertical Maximum.
4”
exhaust and 6-5/8
” combustion air intake coaxial vent pipe required. 12’ maximum horizontal run allowed with 4’ minimum
vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE
: There is one exhaust vent damper included in this unit and located in the top
convection chamber at the center.
CONTROLS
: Thermocouple Safety System with Standing Pilot Thermopile power generator. Thermostat option available.
BLOWER SYSTEM
: 190 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
BURNER SYSTEM
: Single Stainless-Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS
: Externally controllable Burner air shutter.
LOG SET
: 6-piece, Premium Definition Log Set with Extreme glow and realism.
REFRACTORY PANELS
: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas. 4.5”WC
Minimum inlet pressure required.
LPG INFORMATION: LP conversion kit #HA-30-00237 is required. 12
”WC Minimum inlet pressure required.
For the DXV35
Timberfire LPG application, the orifice is to be drill size #50. For higher altitude, adjustment to orifice size may be necessary.
Содержание DXV-60
Страница 14: ...85 03 01115 DXV35 TIMBERFIRE Page 14 Figure 3 10 Figure 3 9...
Страница 36: ...85 03 01115 DXV35 TIMBERFIRE Page 36 Approved Vent Systems Figure 3 29 Approved Vent Systems...
Страница 62: ...85 03 01115 DXV35 TIMBERFIRE Page 62...
Страница 63: ...85 03 01115 DXV35 TIMBERFIRE Page 63...
Страница 64: ...85 03 01115 DXV35 TIMBERFIRE Page 64...
Страница 85: ......
Страница 86: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...