6
Flue and Chimney connection to your stove (continued)
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternately a
draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its
closed position leave a minimum continuous opening free area of at least 20 % of the total cross sectional area of the
flue or flue pipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and connecting
flue pipe
Your appliance needs to be maintained routinely, the throat plate/baffle should be cleaned regularly (monthly) . The
flue pipe can be cleaned using a flexible brush. Only Use a damp cloth on external surfaces. Over time the glass may
become dirty, clean with a damp cloth and polish off with dry cloth. If the stove has not been used for some time the
flue should be checked for blockages before use.
Do not modify the appliance; only use spares authorised by the manufacturer.
STOVE
A
B
C
D
E
SOMERTON 2
510MM
118MM
982MM
75MM
225MM
SOMERTON 2 COMPACT
510MM
118MM
777MM
225MM
SOMERTON 2 PEDESTAL
516MM
118MM
1132MM
150MM
225MM