STOVE PERFORMANCE & TESTING
MENDIP STOVES Somerton stoves are approved and tested in accordance with EN 13240.
Log length
Wood
reload
Weight wood load
Coal reload
Weight coal (anth)
Somerton 2
35cm
1hr
2.1kg
N/a
N/a
Stove model
Weight & Nominal heat output for Wood and Smokeless fuels
Chimney Connection
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught to clear
the products of combustion and prevent smoke problems into the room.
Tested Gas flow
rates flue gas
temperatures
Flue gas flow rate
Wood /coal
Test flue gas temperature
wood /coal
@ pascals of pressure
Somerton 2
4.89/sec
275
⁰C
12 Pa
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the chimney
should be satisfactory. Alternately the calculation procedure given in BS 5854:1980 may be used as the basis for deciding
whether a particular chimney design will provide sufficient draught.
Output wood
fuel
Efficiency
CO@13%
O₂
Recommended
for smoke control
Output coal
fuel
Efficiency CO@13%
O₂
Somerton 2
7.0kW
81.0%
0.21
YES
N/a
N/a
N/a
Tested Gas flow
rates flue gas
temperatures
Flue gas flow rate
Wood /coal
Test flue gas temperature
wood /coal
@ pascals of pressure
Somerton 2
4.89/sec
275
⁰C
12 Pa