10
RE-FUELLING ( wood)
To re-fuel your stove in the cleanest way.
Only refuel your stove when flames have died down and you have glowing embers.
Before refuelling, open UAC fully open to central position .
Open door gently, add three pieces of wood (see weight table page 4) and close the door.
Once the flames from the logs are fully established slide UAC control to right position and leave 100% open position.
The stove is only suitable for intermittent use only: do not run overnight or for long periods unattended. Experience will
determine the settings that produce best results. Use a flue thermostat to check the stove is not overheating. Flue thermostats
should be placed directly above collar of the stove on a non insulated section of pipe. (efficient operating temperature
range is between 200c and 400c) The stove will get very hot during use and due care must therefore be exercised. Please
use the glove when operating air controls and door.
Universal air control
The Universal air control provides primary secondary and tertiary combustion air for the stove from one simple control.
The controlling arm moves in and out for increased or reduced air (power etched on the arm).
To increase the primary air slide lever to the left and
increase secondary air move arm to right.
Secondary air slide right
Full power / pull out
Secondary air slide right
Primary air slide left
Min power / push in