11
1. Fire Will Not Burn - check
a) the air inlet is not obstructed in any way,
b) that chimney and flue ways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply into the room,
e) that an extractor fan is not fitted in the same room as
the fire.
2. Fire Blazing Out Of Control - check
a) the doors are tightly closed,
b) the air controls are turned down to the minimum
setting,
c) the flue damper is closed ( if fitted),
d) a suitable fuel is being used,
e) the door seals are in good condition.
F) the chimney draft may be too strong
G) check ash pan seal and
H) check for ash below ash pan causing pan to seat
incorrectly and clean out.
3) Soot forms on the window
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
c) fire not hot enough
4) The stove fails to heat fully
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
5) Smoke or odour
a) weak chimney draft
b) check for blockages in the flue pipe/chimney
c) check the height of the chimney relative to the
surroundings
6) Soot in the chimney
a) The firewood may be too wet
b) intake of secondary air may be insufficient
This appliances has been approved by HETAS Ltd as an intermittent operating appliance for burning wood .
HETAS recommended fuels
:
Please note that HETAS Ltd Appliance Approval only covers the use of wood logs on this appliance. HETAS Ltd Approval does
not cover the use of other fuels either alone or mixed with the recommended fuels listed above, nor does it cover instructions
for the use of other fuels.
HETAS LTD APPROVAL
TROUBLE SHOOTING