![Memotec NetPerformer SDM-9120 Series Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/memotec/netperformer-sdm-9120-series/netperformer-sdm-9120-series_hardware-installation-manual_1770210055.webp)
Hardware Installation
Memotec Inc.
3-27
3.8
Installing the Ferrites (EMI Filters)
NOTE:
Ferrites are
not
provided with the product package.
Ferrites, or EMI filters, are required in the following circumstances:
•
For E&M/PTT connections on all SDM-9XXX Series products, in all countries.
•
For FXO and FXS connections on the SDM-9XXX Series UAC models, in the
European Union and Russia only. These ferrites ensure compliance with
standard
EN 55024:2010 + A1 + A2
.
provides details on ferrite requirements.
►
To install a ferrite:
1.
Thread the cable from the NetPerformer port through the ferrite opening
2.
Wrap the cable around the ferrite the number of times required for the port, referring
to
.
shows an example of a single wrap around the ferrite.
NOTE:
Wrapping is not required in the case of an E1-75 connection, as the coaxial cable
connected to the RJ48 to BNC adapter is too bulky to permit it.
Port Type
Models affected
Where
required
Ferrite required
Cable
Wrapping
E&M/PTT
All
SDM-9XXX
Series models
All countries
LFB159079-000
(Steward)
4 times
FXO
SDM-9XXX
Series
UAC
models
EU and Russia
only
742 717 33, and
single Wrap (Wurth)
6 times
FXS
SDM-9XXX
Series
UAC
models
EU and Russia
only
742 717 33, and
single Wrap (Wurth)
6 times
Table 3-3 SDM-9XXX Series Ports Requiring a Ferrite
Содержание NetPerformer SDM-9120 Series
Страница 1: ...NetPerformer Hardware Installation Guide SDM 9120 9220 9230 9140...
Страница 10: ......
Страница 68: ...NetPerformer Hardware Installation Guide 3 40 Memotec Inc...
Страница 116: ...NetPerformer Hardware Installation Guide 4 48 Memotec Inc...
Страница 132: ...NetPerformer Hardware Installation Guide 6 6 Memotec Inc...
Страница 133: ...A Appendix A Warranty Information This appendix explains the conditions of the product warranty...
Страница 138: ...NetPerformer Hardware Installation Guide A 6 Memotec Inc...
Страница 143: ...Memotec Inc B 5 Compliance and Regulatory Statements EU Directives EMC Safety RoHS...
Страница 144: ...NetPerformer Hardware Installation Guide B 6 Memotec Inc...
Страница 145: ...Memotec Inc B 7...
Страница 152: ...NetPerformer Hardware Installation Guide B 14 Memotec Inc...
Страница 157: ...Memotec Inc B 19 Compliance to China RoHS...
Страница 160: ...NetPerformer Hardware Installation Guide B 22 Memotec Inc...