11.3.1 Remove cover from ventilation unit
►
Using both thumbs, press the two latches
(item 1 in Fig. 19) on the bottom of the
ventilation unit. The cover will come away.
►
At the same time, push your index fingers
into the gap between the cover and hous-
ing, and lift the cover up from the housing.
11.3.2 Remove filter
►
Turn the filter ring (item 1 in Fig. 20) using the hand grip (item 2 in Fig. 20) anti-clockwise
until the arrow on the filter ring (item 3 in Fig. 20) lines up with the arrow at the removal
►
Pull the filter ring together with the extract air filter out of the ventilation unit.
►
Turn the filter cover (item 6 in Fig. 20)
using the hand grip (item 7 in Fig. 20)
anti-clockwise until the arrow (item 8 in
Fig. 20) on the filter cover lines up with the
arrow at the removal position (item 9 in
►
Pull the filter cover together with the sup
-
ply air filter out of the ventilation unit.
►
Detach the extract air filter from the filter
ring.
►
Detach the supply air filter from the filter
cover.
►
Clean the filter ring and filter cover with a
damp cloth if they are dirty (see section
Fig. 19: Remove cover from the ventilation unit
Fig. 20:
Remove filter