11 Filter maintenance
The level of soiling of the round filter cartridges is automatically monitored by the ventilation unit. A
pending filter change is signalled audibly roughly 2 to 3 weeks in advance.
As the time for the filter change approaches, the intervals between the audible warnings shorten.
The filters must be changed when the warning signal occurs every hour and lasts for one second.
This long warning period allows the user to order replacement filters in good time. No tools are
needed to change the filters.
11.1 Choice of filter
There are several filter classes available for the ventilation unit M-WRG-S/Z-T...:
Part
no.
Designation Filter type
Filter class Application
5571
M-WRG-FS
Standard filter (for
supply air and
extract air)
G4
Normal use
5572
M-WRG-FA
Allergy filter (for
supply air only)
F7
For people with allergies
5573
M-WRG-FK
Activated charcoal
filter (for supply air
only)
M6
For outdoor air polluted by cars,
industry, domestic fuel, etc.
11.2 Ordering filters
You can order replacement filters from your fitter or at
(or using
the QR code on this page).
11.3 Filter change
NOTE
►
Always replace filters in pairs, at least once per year and ideally before the period of cold
weather. The permeability of both filters affects the efficiency and power consumption of
the ventilation unit.
►
Always switch the ventilation unit off at the mains switch for the filter change. Otherwise
the open air flaps will make it impossible to remove and insert the filter cartridges.
Go to
www.ersatzfilter.de