Instructions Manual
4.Function Set-up by Use
4-1.Setting MOTOR SELECT switch
Erroneous setting may cause burn on the
skin due to overheating of the motor.
Ensure correct setting.
The MOTOR SEL switch is turned to the setting
corresponding to the motor in use.
Set this switch with power OFF.
The switch is factory-set to [10L].
(1) Turn power [OFF].
(2) Set the MOTOR SEL switch [10L/5L] to the setting specified in the table
"10-5. Applicable Motors."
4-2.Setting HIGH-SPEED POWER OUTPUT SELECT switch
HIGH-SPEED TORQUE is set up with the POWER SEL switch.
There are four different types of torque characteristics.
The switch is factory-set to [HP,H].
(1) Set the POWER SEL switch [HP/LP][H/L] to the torque characteristic required.
● Relationships of the switch setting and heat generation by the motor and
HIGH-SPEED TORQUE.
● Select the switch [HP,H](ON,ON) if HIGH-SPEED TORQUE is required, and the
switch [LP,L](OFF,OFF) if not, in order to control heat generation
by the motor.
● Selecting one of the switch setting types leads to power demand as shown below:
(Factory setting)
LP,L
120VA
150VA
180VA
HP,L
LP,H
HP,H
(with DRIVE I.SEL No.F set up)
Power Demand
Switch setting
220VA
I
-15-
Содержание GD-5410
Страница 12: ...Instructions Manual 3 Name and Function of Each Section 3 1 Signal I O Connector J1 12 ...
Страница 13: ...Instructions Manual 3 2 AC Input Motor Output Terminal Block J2 J3 13 ...
Страница 33: ...Instructions Manual 10 3 I O Signal R3 1 Example Circuit Connection 33 ...
Страница 39: ...Instructions Manual 10 4 Dimensions Unit mm 39 ...
Страница 42: ...Instructions Manual 42 ...
Страница 43: ...Instructions Manual 43 ...
Страница 44: ...Instructions Manual 44 ...
Страница 45: ...Instructions Manual 45 ...
Страница 46: ...Instructions Manual 46 ...