background image

RedLab 1208FS User's Guide 

Specifications 

31 

Counter 

Table 14. Counter specifications 

Pin name (Note 8) 

CTR 

Counter type 

Event counter 

Number of channels 

Input type 

TTL, rising edge triggered 

Input source 

CTR screw terminal 

Resolution 32 

bits 

Schmitt trigger hysteresis  

20 mV to 100 mV 

Input leakage current 

±1 µA 

Maximum input frequency 

1 MHz  

High pulse width  

500 ns min 

Low pulse width 

500 ns min 

Input high voltage 

4.0 V min, 5.5 V absolute max 

Input low voltage 

1.0 V max, –0.5 V absolute min 

Note 8:  

CTR is a Schmitt trigger input protected with a 1.5K 

 series resistor. 

Non-volatile memory 

Table 15. Non-volatile memory specifications 

EEPROM 1,024 

bytes 

Address Range 

Access 

Description 

0x000-0x07F 

Reserved 

128 bytes system data 

0x080-0x1FF 

Read/write 

384 bytes cal data 

EEPROM Configuration 

0x200-0x3FF 

Read/write 

512 bytes user area 

Microcontroller 

Table 16. Microcontroller specifications 

Type 

High performance 8-bit RISC microcontroller 

Program Memory 

16,384 words 

Data Memory 

2,048 bytes 

Power  

Table 17. Power specifications 

Parameter Conditions 

Specification 

Supply current (Note 9) 

 

80 mA 

Connected to self-powered hub 
Connected to externally-powered root port hub 

4.5 V min, 5.25 V max 

+5V USB power available (Note 10) 

Connected to bus-powered hub 

4.1 V min, 5.25 V max 

Connected to self-powered hub 
Connected to externally-powered root port hub 

420 mA max 

Output current (Note 11) 

Connected to bus-powered hub 

20 mA max 

Note 9:  

 This is the total current requirement for the RedLab 1208FS which includes up to 10 mA for the status 
LED. 

Содержание redlab 1208fs

Страница 1: ......

Страница 2: ...RedLab 1208FS USB based Analog and Digital I O Module User s Guide Document Revision 1 5 E April 2014 Copyright 2014 Meilhaus Electronic...

Страница 3: ...rm Meilhaus Electronic GmbH feels obliged to point out that they cannot be take on neither any warranty apart from the claims for warranty as agreed nor legal responsibility or liability for consequen...

Страница 4: ...Details 13 Theory of operation analog input acquisition modes 13 Software paced mode 13 Continuous scan mode 13 External components 13 USB connector 14 LED 14 Screw terminal wiring 14 Main connector a...

Страница 5: ...RedLab 1208FS User s Guide 5 Microcontroller 31 Power 31 General 32 Environmental 32 Mechanical 32 Main connector and pin out 32 4 channel differential mode 33 8 channel single ended mode 33...

Страница 6: ...Bold text is used for the names of objects on the screen such as buttons text boxes and check boxes For example 1 Insert the disk or CD and click the OK button italic text Italic text is used for the...

Страница 7: ...nter The RedLab 1208FS is powered by the 5 volt USB supply from your computer No external power is required The analog inputs are software configurable for either eight 11 bit single ended inputs or f...

Страница 8: ...IN CAL Screw terminal I O connector Screw terminal I O connector Analog Input 8 single ended 11 bit channels or 4 differential 12 bit channels 1 Analog output 2 channels 12 bit 8 2 Port A Port B Figur...

Страница 9: ...osition DIP switches to set or interrupts to configure You can connect the RedLab 1208FS before or after you install the software and without powering down your computer first When you connect an HID...

Страница 10: ...USB cable 2 meter length Additional documentation In addition to this hardware user s guide you should also receive the Quick Start Guide available on our RedLab CD root directory This booklet supplie...

Страница 11: ...stem software Before you install your RedLab 1208FS run Windows Update to update your operating system with the latest HID and USB drivers To connect the RedLab 1208FS to your system turn your compute...

Страница 12: ...ilhaus com Caution Do not disconnect any device from the USB bus while the computer is communicating with the RedLab 1208FS or you may lose data and or your ability to communicate with the RedLab 1208...

Страница 13: ...acquire data from up to eight channels The analog data is continuously acquired and converted to digital values until you stop the scan Data is transferred in blocks of 31 samples from the RedLab 120...

Страница 14: ...FS is connected to a computer or external USB hub Blinks continuously Data is being transferred Screw terminal wiring The RedLab 1208FS has two rows of screw terminals one row on the top edge of the h...

Страница 15: ...ternal event counter connection CTR Screw terminal pins 21 40 The screw terminals on the bottom edge of the pins 21 to 40 provide the following connections 16 digital I O connections PortA0 to Port A7...

Страница 16: ...Port B3 35 Port B2 34 Port B1 33 Port B0 32 Port A6 27 Port A5 26 Port A4 25 Port A3 24 Port A2 23 Port A1 22 Port A0 21 8 channel single ended mode pin out 20 CTR 19 SYNC 18 TRIG IN 17 GND 16 CAL 15...

Страница 17: ...gh two wires The wire carrying the signal to be measured connects to CH IN The second wire connects to AGND The input range for single ended mode is 10 V No other ranges are supported in single ended...

Страница 18: ...signal of the differential channel must be in the 10 V to 20 V range in order to yield a useful result For example you input a 4 V pp sine wave to CHHI and apply the same sine wave 180 out of phase t...

Страница 19: ...respect to ground all ranges except 20V can realize a linear output for any differential signal with zero common mode voltage and full scale signal inputs The 20 V range is the exception You cannot p...

Страница 20: ...40 Port A0 to Port A7 and Port B0 to Port B7 Refer to the pinout diagrams on page 16 for the location of these pins You can configure each digital port for either input or output When you configure t...

Страница 21: ...llows RedLab 1208FS 80 mA 16 DIO 2 5 mA ea 2 AO 15 mA ea 150 mA For an application running on a PC or powered hub the maximum available excess current is 500 mA 150 mA 350 mA This number is the total...

Страница 22: ...Quite often resolution is incorrectly used to quantify the performance of a measurement product While 12 bits or 1 part in 4096 does indicate what can be resolved it provides little insight into the...

Страница 23: ...tput Code 9 77mV 2048 Figure 12 ADC transfer function with offset error Gain error is a change in the slope of the transfer function from the ideal and is typically expressed as a percentage of full s...

Страница 24: ...no voltage error Combining these two error sources in Figure 14 we have a plot of the error band of the RedLab 1208FS for the 10 V range This is a graphical version of the typical accuracy specificati...

Страница 25: ...reading It can also introduce a long recovery time from saturation which can affect the next measurement in the queue Synchronizing multiple units You can connect the SYNC pin of two RedLab 1208FS un...

Страница 26: ...that use the EXTCLOCK option An example of a master slave configuration is shown below Figure 15 Configuring for synchronous data acquisition When you are operating one RedLab 1208FS do not set the E...

Страница 27: ...ngle ended mode 10 V G 2 Input ranges differential mode 20 V G 1 10 V G 2 5 V G 4 4 V G 5 2 5 V G 8 2 0 V G 10 1 25 V G 16 1 0 V G 20 Software selectable Software paced 250 samples per second S s typ...

Страница 28: ...ge Accuracy LSB 10 V 4 0 Table 4 Accuracy components differential mode All values are Range of Reading Gain Error at full scale FS millivolts mV Offset mV Accuracy at FS mV 20 V 0 2 40 9 766 49 766 10...

Страница 29: ...9 Analog output accuracy all values are Range Accuracy LSB 0 4 096 V 4 0 typ 45 0 max Table 10 Analog output accuracy components all values are Range of FSR Gain Error at FS mV Offset mV Note 5 Accur...

Страница 30: ...series resistor External clock input output Table 13 External clock I O specifications Parameter Conditions Specification Pin name SYNC Pin type Bidirectional Output default Outputs internal A D pace...

Страница 31: ...Access Description 0x000 0x07F Reserved 128 bytes system data 0x080 0x1FF Read write 384 bytes cal data EEPROM Configuration 0x200 0x3FF Read write 512 bytes user area Microcontroller Table 16 Microco...

Страница 32: ...In this case the maximum current available from the USB 5 V is 100 mA The minimum USB 5 V voltage level can be as low as 4 1 V Note 11 This refers to the total amount of current that can be sourced fr...

Страница 33: ...14 D A OUT 1 34 Port B2 15 AGND 35 Port B3 16 CAL 36 Port B4 17 GND 37 Port B5 18 TRIG IN 38 Port B6 19 SYNC 39 Port B7 20 CTR 40 GND 8 channel single ended mode Pin Signal Name Pin Signal Name 1 CH0...

Страница 34: ...Meilhaus Electronic GmbH Am Sonnenlicht 2 D 82239 Alling Germany Phone 49 0 8141 5271 0 Fax 49 0 8141 5271 129 E Mail sales meilhaus com http www meilhaus com...

Отзывы: