49 / 56
9760465
10.
Options
ActiveClean water softener (if applicable)
Check water hardness setting
U/H
annually
Check the seal on the lid of the salt container
U/H
annually
Start and check the regeneration process manually
U/H
annually
Integrated reverse osmosis system (if applicable)
Visually check whole system for leaks
U/H
annually
Prefilter change standard membrane (< 0.1 mg/l)
U/H
every six
months
Change pre-filter, chlorine-
resistant membrane (≥ 0.1 and ≤ 2.0
mg/l)
U/H
every three
months
Check fine sieve insert and choke in concentrate pipeline
U/H
annually
Check correct function of concentrate drain and check for deposits
U/H
annually
Fill in separate log:
Certificate of Commissioning, GiO
U/H
annually
Partial demineralisation (PD)/full demineralisation (FD) (if applicable)
Check operation
U/H
annually
Exhaust air heat recovery (if applicable)
Check operation of fan
H
annually
Check operation of solenoid valve
H
annually
Carry out visual inspection and check for leaks
H
annually
9.3
Daily cleaning
Caution
Material damage due to water ingress
Electrical cables and electronic components can be damaged if they come into
contact with water.
• The dishwashing machine, switch cabinets and other electrical components
must
never
be sprayed with a hose or high pressure cleaner.
• Make sure that no water can enter the machine unintentionally.
• If installed at ground level,
never
flood the surrounding room.
Note
Do not use a foaming detergent for dish-washing by hand for pre-cleaning or clean-
ing the dishwasher. Foam causes malfunctions and results in poor wash results.
The machine is emptied, see chapter “Shutting down the dishwasher” on page 35.
1. Open door.
Содержание UPster H 500 M2