Page 17 G1
CONFIGURATION
The Cashlow
©
2612 can be manually configured using a bank of eight option switches.
The Cashflow
©
2612 can also be configured using a configuration coupon.
Factory Configuration
The Cashflow
©
2612 Note Acceptor is factory configured with all switches in the OFF position.
The following configuration is programmed:
•
Maximum directions for note acceptance (four-way)
•
High acceptance
•
€5; €10 Euro note enabled
•
1 pulse per Euro
•
MDB Interface
The unit will default to these selections whenever all option switches are OFF. Placing any
switch ON will override the factory settings and the note acceptor will operate according to the
switch settings you choose.
If the Cashflow
©
2612 is reprogrammed using a coupon with a different configuration, the new
configuration will be the default.
I
f any option switch is turned ON, the option switch settings
will override the coupon setting. The coupon configuration will remain in memory.