12
AUTO CLEANING:
1.
Make sure the air and power are still connected to the machine and enough filled rows of
bottles remain on the machine for proper feeding. Also leave at least 3 rows of empty
bottles on the bottle feed ramp.
2.
Connect the product hose to the sanitizing pump ensuring the other end is connected to
the product manifold on the bottling machine.
3.
Immerse the sanitizing pump in an adequate volume of clean water or cleaning solution.
Most cleaning solutions are acceptable with the exception of acid based materials that can
damage the internal parts of valves used in the off-gas system. Remember you will be
filling 2 rows of bottles and washing through the off-gas system.
4.
Disconnect the 5/32" liquid pressure sensor hose (small tubing) from the pressure sensor
located in the bottom of the control panel. To disconnect the hose, depress the collar of
the tube fitting and pull the hose out. Place the end of the hose you just disconnected
below the machine into a bucket or drain. Cleaning solution will flow through this line
when the pump is started in the next step.