5 OPERATING INSTRUCTIONS
5.4 Measurement using P/F
– pass/fail
1]
Make the desired settings in the
SET
options
Select
P/F
and enter desired limit value.
In this example
LOG
is set to OFF
2]
Turn the function selector to one of the test
positions.
3]
Press the
TEST
button on MOM2 or the
pull
the trigger on the probe.
A continuous audio signal tells that the
measurement is in progress.
Another signal tells that the measurement is
complete, pass or fail.
A]
If the resistance value is below the
P/F
limit.
The result will be shown on the display with
big digits.
The small digits toggle between the
P/F
limit
and the max, min current values.
Here P/F limit was set to 150 µΩ and the measured resist-
ance value is 100 μΩ.
Max current during test was 219 A.
Min current during test was 205 A
B]
If the resistance value is over the
P/F
limit
there is the fail signal and the > character is
displayed to the left of the set
P/F
value.
The small digits show the set
P/F
value (< 90 μΩ).
The character ">" to the left of the big digits indicates that
the P/F value was exceeded.
The minimum current was 80 A and the resistance value is
102 μΩ.
Содержание MOM2
Страница 1: ...WWW MEGGER COM User s Manual MOM2 MOM2 Win Micro ohmmeter Art No ZP BD03E Doc BD0333FE V06a 2016...
Страница 2: ......
Страница 13: ...BD0333FE ZP BD03E MOM2 13 4 Functions and set up...
Страница 31: ...BD0333FE ZP BD03E MOM2 31 6 Application examples...
Страница 43: ...BD0333FE ZP BD03E MOM2 43...
Страница 46: ...46 MOM2 ZP BD03E BD0333FE Index...
Страница 47: ......