Megger BERT-20E1 Скачать руководство пользователя страница 12

The BERT-20E1 offers ten operating modes. Modes of operation are
selected by using the up/down arrow keys located under the MODE
section of the instrument’s upper panel. 

NORM –Normal Mode

In the NORM mode the receiver and transmitter are manually configured
for frame, pattern and line code via their respective up/down arrow
keys in the default/results menu.  

The transmitter setup menu is not available in this mode of operation.
The transmitter settings will be coupled to that of the receiver. 

AUTO – Automatic Detection Mode

This mode allows the user to originate a 2.048 Mbps signal and BERT.
The Transmitter and Receiver are independent. The receiver is always in
the automatic detection mode looking for framing, pattern and line code.  

The transmitter can be set up by pressing the TRANSMITTER SETUP key.
The operator will know they are in the transmitter setup menu because
the green LED located next to the transmitter setup button will
illuminate and the text "TX SETUP MENU" will appear on the first line of
the LCD.

Fx56 – Fractional E1 (Nx56) Mode

This mode allows the user to test in a Fractional E1 environment. Only 7
bits of data are available in each timeslot. The receiver and transmitter
are manually configured for frame, pattern and line code via their
respective up/down arrow keys in the default/results menu.  

The transmitter setup menu is not available when operating in this
mode. The channels are configured by selecting AUX function 03 in the
auxiliary menu (AUX). 

Fx64 – Fractional E1 (Nx64) Mode

This mode allows the user to test in a fractional E1 environment. The
full 8-bits of data are available in each time slot. The receiver and
transmitter are manually configured for frame, pattern and line code via
their respective up/down arrow keys in the default/results menu. 

The transmitter setup menu is not available when operating in this
mode. The channels are configured by selecting AUX function 03 in the
auxiliary menu (AUX). 

D/I – Half Duplex Drop and Insert

This mode allows the user to drop an individual time slot to the speaker
and receiver BERT engine. At the same time, either pattern data or a
tone may be inserted into the out-going channel. The other 31 channels
of the frame are left undisturbed. The receiver and transmitter are
manually configured for frame and line code via their respective
up/down arrow keys in the default/results menu. The PATTERN
up/down arrow keys select either an IDLE or INSRT condition.   

The drop channel is selected via the TS/CHANNEL select keys on the
front panel. The transmitter setup menu selects the desired insertion data
channel and whether pattern data or analog tone (frequency/level) is
inserted into the channel. 

TONE – Tone Insertion Mode

This mode allows the user to insert fixed frequencies of 404 Hz, 1004 Hz
and 2804 Hz, or swept tones from +3 dB to -50 dB. The receiver and
transmitter are manually configured for frame and line code via their
respective up/down arrow keys in the default/results menu. The
PATTERN up/down arrow keys select either an IDLE or INSRT condition.  

The frequency, level and insert channel is selected via the transmitter
setup menu. 

12

SELECTING OPERATING MODES

BERT_20E1_6172-871_UG_V02  05/05/2004  8:24 am  Page 12

Содержание BERT-20E1

Страница 1: ...M BERT 20E1 2 048 Mbps Network Analyzer USER MANUAL BERT_20E1_6172 871_UG_V02 05 05 2004 8 24 am Page 1...

Страница 2: ...propriate surge and transient protection has been fitted The network and user terminals may be raised to hazardous voltages if this unit is connected to non SELV circuits This instrument should not be...

Страница 3: ...5 Software Revision Supplied Equipment Handling Precautions Front Panel Features Test Modes Frame Structures Test Patterns Line Codes Auxiliary Functions Power Batteries CONNECTING TO THE NETWORK 10 C...

Страница 4: ...cularly in environments where a convenient power supply may not be available Measurement Summary The BERT 20E1 combines BER test functions along with signal qualitymeasurement providing the ability to...

Страница 5: ...en the unit is initially powered up Supplied Equipment The BERT 20E1 is supplied with the following items A C power adapter User manual including CD ROM based E1 basics Carrying case Rubber boot Handl...

Страница 6: ...LUME controls BATTERY STAUS indicator TS CHANNEL SELECTION keys and display Stores test configuration Recalls test configuration Selects circuit termination Injects LOGIC BPV or FRAME CRC errors Power...

Страница 7: ...mode TONE Tone insert mode LLB Local loop back mode TLB Test loop back mode DLAY Round trip loop delay measurement CO64 Co directional 64kbps mode NONE No Framing P31 No multiframing P31C CRC multifr...

Страница 8: ...ITU T O 151 O 152 O 153 211 1 as per ITU T O 151 O 152 O 153 215 1 as per ITU T O 151 O 152 O 153 220 1 as per ITU T O 151 O 152 O 153 223 1 as per ITU T O 151 O 152 O 153 1 1 Alternating ones and ze...

Страница 9: ...BERT 20E1 batteries are not serviceable To recharge the batteries connect the 9 VDC power source to the DC jack located on the front panel The test set will charge during operation but it is recommen...

Страница 10: ...ction of 120 balanced data signals 120 TRANSMIT Transmitter output interface Provides 120 balanced data output EXT CLOCK IN Allows connection of a 75 timing reference as per ITU T G 811 The reference...

Страница 11: ...nuation Typically this gives a test signal 30 26 20dB down on the traffic signal Select MON monitor as your receive interface termination Next choose the appropriate MONITOR GAIN from the BERT 20E1 s...

Страница 12: ...4 Mode This mode allows the user to test in a fractional E1 environment The full 8 bits of data are available in each time slot The receiver and transmitter are manually configured for frame pattern a...

Страница 13: ...ing the logic error inject key the test set will insert a single logic error into the E1 payload At the same time a 1 millisecond counter is started and the receiver will start looking for the bit err...

Страница 14: ...E1 has achieved pattern synchronization by observing the green PATTERN SYNC LED under the RX STATUS heading on the front panel of the unit Each time the test set detects an error in the logic bit stre...

Страница 15: ...ed will be measured and the received level or amplitude will be displayed The BERT 20E1 demodulates the digitally encoded signal on the selected channel and drops the channel to the speaker The level...

Страница 16: ...rror seconds parameter is a one second interval of an available second where one or more bit errors have occurred The error free seconds parameter is a one second interval of an available second where...

Страница 17: ...to OFF The ERROR INJECT RATE menu can only be accessed when operating in the NORM AUTO F x 56 F x 64 D I LLB or TLB modes 03 User Pattern 1 The user pattern 1 is a user defined patterns that is 32 bi...

Страница 18: ...l Fx56 Fx64 LLB or TLB and the printer is correctly hooked up and configured correctly The following sample printout will be observed TEST RESULTS TIME CURRNET TIME DATE CURRENT DATE MODE NORM FRAME P...

Страница 19: ...ular DIN Custom EXT CLOCK IN 75 BNC Auxiliary Power DC power jack accepts 2 5 mm diameter female plug with center or tip and outside Receiver Modes NORM Tx follows Rx AUTO Auto Configure Rx Tx is inde...

Страница 20: ...G 706 G 823 G 732 and I 431 ETS 300 011 300 233 and 300 166 CTR12 and CTR4 Transmitter Line Code AMI or HDB3 Framing NONE PCM30 PCM30C PCM31 and PCM31C Frequency 2048000 Hz 2 5 ppm Line Coding AMI HDB...

Страница 21: ...ORM SUMMARY PERFORMANCE Clock Slips A positive number indicates that the reference clock is faster a negative number indicates that the reference clock is slower Errors Logic rrrors logic error rate B...

Страница 22: ...rsonnel The test set circuit contains static sensitive devices and care must be taken in handling the printed circuit board If the protection of a test set has been impaired it should not be used and...

Страница 23: ...23 BERT_20E1_6172 871_UG_V02 05 05 2004 8 24 am Page 23...

Страница 24: ...30 16 08 90 F 33 0 1 34 61 23 77 OTHER TECHNICAL SALES OFFICES Toronto CANADA Sydney AUSTRALIA Mumbai INDIA Madrid SPAIN and the Kingdom of BAHRAIN Megger products are distributed in 146 countries wo...

Отзывы: