LP-Gas Supply System
•
If this information is not followed exactly, a fire
resulting in death or serious injury could occur.
•
A 9kg LP gas cylinder of approximately 30cm in
diameter by 52cm high is the maximum size LP
gas cylinder to use.
•
The safety feature prevents the cylinder from
being overfilled, which can cause malfunction of
the LP gas cylinder, regulator and/or braai.
•
The LP gas supply cylinder to be used must be
constructed and marked in accordance with the
specifications for LP Gas cylinders in RSA.
•
The LP gas cylinder must have a shut off valve
terminating in an LP valve outlet that is
compatible with a Type 1. LP gas supply cylinder
must have a shut off valve terminating in a valve
outlet specified for connection type QCC1 in the
standard for compressed gas cylinder valve outlet
and inlet connection. LP gas supply cylinder must
be fitted with an Overfill Protection Device (O.P.D)
The LP gas cylinder must also have a safety
relief device that has a direct connection with the
vapour space of the cylinder.
•
The cylinder supply system must be arranged for
vapour withdrawal.
•
The LP gas cylinder used must have a collar to
protect the cylinder valve.
•
Place dust cap on cylinder valve outlet whenever
the cylinder is not in use. Only install the type of
dust caps on the cylinder valve outlet that is
provided with the cylinder valve. Other types of
cap or plugs may result in leakage of gas.
•
Never
connect an unregulated LP gas cylinder to
your gas braai.
•
This outdoor cooking gas appliance is equipped
with a high capacity hose/regulator assembly for
connection to a standard 9kg LP gas cylinder.
•
Have your LP gas cylinder filled by a reputable
LP gas dealer and visually inspected and re-
qualified at each filling.
•
Do not store a spare LP gas cylinder in the
vicinity of this appliance.
•
Never fill the cylinder beyond 80 percent full.
•
Always keep LP gas cylinders in an upright
position.
•
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance.
•
Storage of an outdoor cooking gas appliance
indoors is permissible only if the cylinder is
disconnected and removed from the outdoor
cooking gas appliance.
•
When your gas braai is not in use the gas must be
turned off at LP gas cylinder.
•
The gas must be turned off at the supply cylinder
when the outdoor cooking gas appliance is not in
use.
•
LP gas cylinder must be stored outdoors in a well-
ventilated area and out of reach of children and
pets. Disconnected LP gas cylinders must not be
stored in a building, garage or any other enclosed
area.
•
Do not obstruct the flow of ventilation air around the
gas braai housing. Only use the regulator and the
hose assembly supplied with your gas braai.
Replacement regulators and hose assemblies must
be those specified in this manual.
•
The regulator and hose assembly must be
inspected before each use of the braai. If there is
excessive abrasion or wear or if the hose is cut or
damaged, it must be replaced prior to the braai
being operated. The replacement hose assembly
shall be that specified by the manufacturer.
•
Pressure regulator and hose assembly supplied
with the outdoor cooking gas appliance must be
used. Never substitute other types of regulators.
Contact customer service for manufacturer
specified replacement parts.
•
This outdoor cooking gas appliance is equipped
with a pressure regulator that complies with the
standard for LP gas products in South Africa.
•
The braai is designed for optimum performance
without the use of briquettes, charcoal or wood. Do
not place briquettes, charcoal or wood on the
radiant as this will block off the area for the braai
burners to vent. Adding briquettes can damage
ignition components and knobs, and void the
warranty.
•
Keep the back and sides of the cart free and clear
from debris. Keep any electrical supply cords, or
the rotisserie motor cord away from the heated
areas of the braai.
•
Never use the braai in extremely windy conditions.
If located in a consistently windy area (oceanfront,
mountaintop, etc.) a wind shield will be required.
Always adhere to the specified clearance area of
61 cm.
•
Never use a dented or rusty LP gas cylinder.
•
Keep any electrical supply cords and the fuel
supply hose away from any heated surfaces.
•
While igniting the braai, keep your face and hands
as far away from the braai as possible.
5