Minimum clearance from the sides and back of
the unit to combustible constructions is, 61cm
from the sides and 61cm from the back.
All internal packaging removed.
Knobs turn freely.
Burners are tight and sitting properly on orifices.
Pressure regulator connected and set. Gas
connections to braai using hose & regulator
assembly provided for 9kg LP gas cylinder.
Unit tested and free of leaks.
User informed of gas supply shut off valve
location.
USER, PLEASE RETAIN THIS MANUAL FOR
FUTURE REFERENCE.
LP GAS CYLINDER CAUTIONS
a)
Do Not store a spare LP gas cylinder under or
near this appliance.
b) NEVER fill the cylinder beyond 80 percent full.
c)
If the information in “a” and “b” is not
followed exactly, a fire or explosion causing
death or serious injury may occur.
General
Although all gas connections on the braai are leak
tested at the factory prior to shipment, a complete
gas tightness check must be performed at the
installation site due to possible mishandling in
shipment, or excessive pressure unknowingly being
applied to the unit. Periodically check the whole
system for leaks following the procedures listed
below. If the smell of gas is detected at anytime you
should immediately check the entire system for leaks.
Before testing
Make sure that all packing material is removed from
the braai including tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING.
NEVER PERFORM LEAK TEST WITH AN OPEN
FLAME.
Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush, or
rag to apply the solution to the fittings. For the initial
leak test, make sure the LP gas cylinder is 80% full.
To test
1.
Make sure the control valves are in the “OFF”
position, and turn on the gas supply.
2.
Check all connections from the LP gas
regulator and supply valve up to and including
the connection to the manifold pipe assembly
(the pipe that goes to the burners). Soap
bubbles will appear where a leak is present.
3.
Only those parts recommended by the manufacturer
should be used on the braai.
4.
Substitution will void the warranty. Do not use the
braai until all connections have been checked and
do not leak.
Gas flow check
Each braai burner is tested and adjusted at the
factory prior to shipment; however, variations in the
local gas supply may make it necessary to adjust the
burners. The flames of tips, excessive noise or lithe
burners should be visually checked.
Flames should be blue and stable with no yellow. If
any of these conditions exist, check to see if the air
shutter or burner ports are blocked by dirt, debris,
spider webs, etc. If you have any questions
regarding flame stability, please call customer care.
ALWAYS CHECK FOR LEAKS AFTER EVERY LP
GAS CYLINDER CHANGE
Check all gas supply fittings for leaks before each
use. It is handy to keep a spray bottle of soapy
water near the shut-off valve of the gas supply line.
Spray all the fittings. Bubbles indicate leaks.
28
Installation final check list
Leak test