Operation
Getting Started
On first use, the 977CM needs to be configured to suit the type of installation and the
type of ionising equipment connected to it. This includes basic settings of the Output
Power, Rate and Balance as well as alarm functionality and the lock option.
Setting the Start Voltage and Ion Output Set Point
During installation and commissioning two parameters must be set correctly to allow
optimum performance.
1. Start Voltage. The correct start voltage must be set, depending on the ioniser
connected to the 977CM. The correct start voltages for Meech ionisers are:
971
15 kV
242
10 kV
251
8 kV
261
7.2 kV
271/272/273
7 kV
2. Ion Output Set Point: This is the target Ion Output as measured when the system
is clean. The 977CM self adjusts to try to maintain the output at this level.
This value should only be set when the ionisers have been cleaned,
otherwise the performance of the system will be reduced
During use, ionisers become contaminated which reduces their performance. The
977CM counteracts this by increasing the output voltage to maintain a consistent
performance. The output voltage will automatically be raised up to a maximum of
125% of the pre-set start voltage.