The implementation of a feed back sensor bar allows this measurement and
adjustment to happen continuously. This results in the most accurate neutralisation
possible, regardless of changing conditions.
The positioning of the sensor bar is critical. It must be located such that it detects the
voltage on the material only and is not influenced directly by the Model 971 Pulsed
DC Ionising bar. Your Meech engineer will be able to advise you on this. General
examples of positioning follow.
Feedback Setup
1.
Switch off the 977CM and connect the feedback sensor bar using the 2.5mm jack
plug.
2. Switch on the 977CM. The LCD display will now display an additional
bargraph that represents the voltage being detected by the sensor bar.
971 Bars
988 Sensors
Wound Reel
971 Pulsed DC Bar
Web Path
988 Sensor