Emitter pins can be cleaned very effectively with a brush. A dry toothbrush is ideal.

Ionisers will need periodic wiping to clean grey deposits from the surface of the bar. A 
cloth moistened with a small amount of IPA or methylated spirits is recommended. 

10

Содержание 976EX

Страница 1: ...Model 976EX Operating Manual Long Range DC Bar...

Страница 2: ......

Страница 3: ...For further information please refer to our Head Office or visit www meech com Meech Static Eliminators Ltd 27 10 17 Contents Introduction 3 Certification 4 Unpacking and Inspection 4 Installation 5...

Страница 4: ......

Страница 5: ...The emitter pins are resistively coupled to the high voltage pulsed DC source rendering the emitters shockless to touch The emitter pins are removable to enable cleaning or replacement The extruded pr...

Страница 6: ...to 35 Model 976Ex Meech Static Eliminators Ltd Witney Oxon OX29 OYN UK Tel 44 1993 706700 Fax 44 1993 776977 e mail sales meech com web www meech com II 2 GD EEx m 1180 Gas group IIB temp Class T6 T85...

Страница 7: ...g the brackets provided The bracket should be positioned on a maximum 500mm pitch The M6 bolts must be used to secure the 976EX bar to the machine frame The Meech Model 976EX must be connected to the...

Страница 8: ...EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS Connect the mains supply to the Pulsed DC Controller and switch ON The 976EX Bar will now produce Pulsed DC ionisa...

Страница 9: ...rate should be set towards its maximum If the polarity of the static charge to be removed is known the Balance can be adjusted to give a faster decay speed I E a If the static charge is known to be po...

Страница 10: ...EX 4 The bar is suitable for installation only in areas where there is a low risk of impact damage 5 The plastic conduit must be securely clamped within 100mm of the bar 6 The user must determine in c...

Страница 11: ...t However equipment used in some heavy contamination areas such as gravure printing or where plastic fumes are present may require daily cleaning Equally in a Class 100 area cleaning may only be requi...

Страница 12: ...very effectively with a brush A dry toothbrush is ideal Ionisers will need periodic wiping to clean grey deposits from the surface of the bar A cloth moistened with a small amount of IPA or methylate...

Страница 13: ...eech Model 910 Water Resistant Ionising Bars makes no contact with water or water based fluids Should such an event occur disconnect immediately and return equipment to the manufacturer for water dama...

Страница 14: ...10 Disconnect all bars from the controller 11 Reconnect the supply and switch on the unit 12...

Страница 15: ...nimum power 4kV and at maximum power 8 kV 13 Having checked the power supply reconnect one Model 976EX Bar 14 Using a high voltage probe RS 610 281 and meter RS 610 590 measure the voltage on the pins...

Страница 16: ...number and must be shipped prepaid For prompt service ship the unit to the factory with the return authorisation number shown clearly on the label Be sure that it is well packed in a sturdy carton wi...

Страница 17: ...extrusion Emitters Titanium replaceable Mounting Universal via T slots fitted with 2 x M4 x 20mm studs as standard T slots are located on three sides of the bar to allow mounting flexibility CE Appro...

Страница 18: ......

Страница 19: ......

Страница 20: ...780 St Vith Belgium Tel 49 0 6555 3733 399 32 0 80 670 204 Fax 32 0 80 862 821 email mesa meech com Meech Shavotech Shavo House Survey No 21A 10 B Plot No 394 South Main Road Koregaon Park PUNE 411 00...

Отзывы:

Похожие инструкции для 976EX