8
Special Conditions for Safe Use
1. The 976EX eliminator bar shall be used in conjunction with either Meech Type
977v3 or Type 977HL power supplies.
2. The power supply must be protected by a fuse capable of withstanding a
prospective short circuit current of 4000A
3. The bar shall be installed according to the manufacturer’s installation instructions
for model 976EX.
4.
The bar is suitable for installation only in areas where there is a low risk of impact
damage.
5. The plastic conduit must be securely clamped within 100mm of the bar.
6. The user must determine, in consultation with Meech, the suitability of the
apparatus for use with particular solvents.
7. When used in dust environments, the equipment may not be used in association
with dusts having an electrical resistance equal to or less than 10
3
Ω.m.
8. When used in dust environments, the equipment may be used only with dusts
requiring an ignition energy of greater than 0.06mJ.
Содержание 976EX
Страница 1: ...Model 976EX Operating Manual Long Range DC Bar...
Страница 2: ......
Страница 4: ......
Страница 14: ...10 Disconnect all bars from the controller 11 Reconnect the supply and switch on the unit 12...
Страница 18: ......