GB
36
STORAGE AND DISPLAY OF MEASURMENT DATA
The instrument automatically saves the 10 last measurements in the reverse order� If the
button is pressed when the instrument is in standby mode, the measurement data is
displayed with the first result as measurement no� 1, see the diagram on the right� When
the the 10 memory slots in the data memory are full the oldest measurement is deleted
and the current measurement is saved in the memory�
TROUBLESHOOTING
MESSAGE CODES
MESSAGE CODE
CAUSE
ACTION
101
Battery discharged
Replace the battery�
104
Calculation error
Repeat process�
152
Temperature too high
Allow the instrument to cool�
153
Temperature too low�
Warm up the instrument�
154
Outside the measurement
range
Measuring can only take place in the interval
0�2 to 20 m�
155
Signal strength too low
Prepare the object to be measured�
156
Signal stength too high
Prepare the object to be measured�
157
Measurement error, or
overbright background
Darken object or change object�
160
Vibration/unstable
Stabilise the instrument and repeat the
measurement�
Jula reserves the right to make changes� In the event of problems, please contact our service department�
www�jula�com