background image

 

TECHNICAL DATA

ECO

240

280

360

Power supply

230 V 50HZ

Motor power rating

276 W

Absorbed consumption

1.3 A

Capacitor

12 uf

Maximum pressure

40 bar

Rod stroke length

242 mm

282 mm

362 mm

Closing manoeuvre time

20 s

24 s

31 s

Opening manoeuvre time

17 s

19 s

26 s

Closing force

637 Kg

Opening force

508 Kg

Maximum gate length

3 m

4 m

6 m

Temperature range

-15 to 80 °C

Thermal protection

100 °C

Group weight

11 Kg

11.5 Kg

12 Kg

 

PRESTACIONES

ECO

SB BAC

HYDRAULIC CLOSURE OUTPUT

LOCK IN BOTH MANOEUVRES

 

LOCK AT CLOSURE

 

LOCK AT OPENING

 

REVERSIBILITY IN BOTH  

MANOEUVRES

WINDPROOF REGULATION

 

MAXIMUM

ECO240

ECO280

ECO360

A

985 mm

1.065 mm

1.225 mm

B

915 mm

995 mm

1155 mm

C

673 mm

713 mm

793 mm

D

242 mm

282 mm

362 mm

TECHNICAL DATA

MODEL: ECO

Содержание ECO240 BAC

Страница 1: ...INSTRUCTION MANUAL AUTOMATIC GATE MECHANISM ECO240 BAC SB 1 3 ECO280 BAC SB 1 3 ECO360 BAC SB 1 3 Ref A40000 V3 ES I...

Страница 2: ...be incorporated or of which it will be a component has been identified and declared to comply with the terms of Directive 2006 42 EEC and subsequent amendments We put the CE conformity marking on the...

Страница 3: ...ty Always install a differential with a value of 0 03 A and a thermomagnetic switch with an opening of the contacts of at least 3 mm provided with overload and short circuit protection Connect the yel...

Страница 4: ...ing force 637 Kg Opening force 508 Kg Maximum gate length 3 m 4 m 6 m Temperature range 15 to 80 C Thermal protection 100 C Group weight 11 Kg 11 5 Kg 12 Kg PRESTACIONES ECO SB BAC HYDRAULIC CLOSURE O...

Страница 5: ...n frequency may be reduced by up to 20 T Time Hours WORK AREA F utilisation factor Ta opening time Tc closing time Tp pause time between opening and closing Ti time between complete manoeuvres opening...

Страница 6: ...90 105 140 180 90 110 125 180 90 115 115 180 90 OPENING OUTWARDS Fig 3 M A B C 85 200 180 100 90 180 180 100 95 165 180 100 100 150 180 100 105 125 180 100 ECO 280 OPENING INWARDS Fig 2 M A B C 85 150...

Страница 7: ...n line emerges on which dimensions A and B may be obtained Fig 2 Page 5 It is important to be as close to the thick vertical line as possible Dimension C remains constant in both motors model 360 C 90...

Страница 8: ...Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 7 of 9 ASSEMBLY INSTRUCTIONS...

Страница 9: ...mit switch ring over the rod Fig 9 to the front cap and fasten it with the Allen screw Now we can activate the motor electrically Reposition the ring if the opening is not as desired 6 Once the motor...

Страница 10: ...motor from below LOCKING OPERATION The BAC system incorporated in the ECO device offers a wide variety of possibilities Here is how it should be manipulated to get the most out of its performance EME...

Страница 11: ...ot an obstacle that must be released In order to be able to do without a limit switch when opening it is necessary for the panel to have the option that when the gate is opening finds an obstacle reve...

Страница 12: ...ECO BAC AUTOMATIC MOTOR...

Страница 13: ...pump 0 90 Cm3 Rev 2M 70884 06 19 Lobe pump ball joint 70538 02 20 Cover seal 90 x 90 x 1 5 70019 01 21 Lobe pump adaptation 70832 04 22 M5 x 42 DIN 912 8 8 screw 80170 23 Electric motor 80x45xh75 230...

Страница 14: ...POWER SUPPLY 230 Vac 50 hz CONSUMED POWER 276 W CONDENSER 12 pF RPM ELECTRIC MOTOR 1500 rpm ELECTRICITY CONSUMPTION 1 3 A TEMPERATURE RANGE 15 C 70 C THERMAL PROTECTION 130 C IP PROTECTION LEVEL IP 6...

Страница 15: ...URE RANGE 15 C 80 C THERMAL PROTECTION 130 C IP PROTECTION LEVEL IP 65 ROD PATH 362 mm ENTRY TIME opening 52 sec ROD EXIT TIME Closing 62 sec MAXIMUM CIRCUIT PRESSURE 40 BAR PUMP FLOW 1 3 l m TYPE OF...

Страница 16: ...MEDVA Mecanismos del Vall s S L C Nataci n 26 28 nave 5 Pol gono Industrial Can Roses 08191 RUB Barcelona Spain 34 93 588 50 37 34 93 588 35 03 info medva es www medva es...