Using the Command and Response Table
The Command and Response Table on the following pages lists valid ASCII command
codes, the responses of the MLC to the host, and a description of the command function
or the results of executing the command. The ASCII to HEX conversion table below is for
use with the table.
ASCII to Hex Conversion Table
•
Space
Symbol Definitions
]
= CR/LF (carriage return with line feed) (hex
0D
0A
)
}
= Soft carriage return (no line feed) (
|
or hex
0D
)
• = Space
E
= Escape key (
W
or
hex
1B
)
X!
= Button number:
01
,
02
,
03
,
04
,
05
,
06
,
07
,
08
,
09
, or
10
Buttons are numbered from front panel top left (
01
) to bottom right (
10
).
NOTE:
The
Mute
button on the MLC 64 VC D cannot be configured, therefore it has
no number.
X@
= Relay port number
1
= Relay 1
2
= Relay 2
X#
= Pulse length in increments of 0.5 seconds. The default is
1
(0.5 seconds).
1
= 0.5 seconds
2
= 1 second
...
255
≈ 130 seconds
X^
= Digital input state
0
= low
1
= high
X*
= Firmware version number (displayed to two decimal places:
n
.
nn
)
X(
= Volume range level (a 3-digit number; for serial drivers with volume tables
only)
NOTE:
Only positive values are allowed. The volume table levels start with zero.
X1!
= Lockout (executive) mode
0
= Off
1
= On
MLC 60 Series MediaLink Controllers • SIS Control
57