Troubleshooting
Copyright © 2015
29
A partial reset will also modify the following parameters to their default value:
Service
Parameter
Default Value
Users.Password
User(s) from profile are restored
with their factory password.
All other usernames keep their
password.
Users.AccessRights
User(s) from profile are restored
with their factory rights.
AAA
ServicesAaaType (table)
Each service will be configured to
use Local authentication and no
accounting mechanism.
EnableTelnet
Disable
TelnetPort
23
EnableSsh
Enable
CLI
SshPort
22
HOC
ManagementInterface
Lan1
EnableSnmpV1
Disable
EnableSnmpV2
Disable
EnableSnmpV3
Enable
SNMP
Port
161
ServerPort
80
HTTPMode
Both
Web
SecureServerPort
443
Performing a Partial Reset
Before you start
To fully understand the changes the partial reset will apply to your configuration, refer to
(p. 28)
.
It is not recommended to access the unit on a regular basis through the Rescue Network Interface.
Steps
1)
When the Power LED is steady or blinking rapidly, insert a small unbent paper clip into the Reset/
Default switch located at the front of the unit.
The Power LED will start blinking.
2)
Wait a few seconds.
3)
When all LEDs are blinking, but before they stop blinking, remove the paper clip.
You have between 7 to 11 seconds.