Hardware Installation Guide - Mediatrix Sentinel
10
Requirements
Location Requirements
To avoid premature aging of the unit, insure user security and facilitate access, upgrades and maintenance,
the following guidelines must be followed.
• Install the Mediatrix unit:
— on a standard 48.26 cm (19 in.) equipment rack.
— on a flat surface (desk, table, etc.).
• Install the Mediatrix unit in a well-ventilated location where it will not be exposed to high temperatures or
humidity.
— Operating temperature: 0ºC to 40ºC.
— Humidity lower that 85% and non-condensing.
• Do not install the Mediatrix unit in a location exposed to direct sunlight or near stoves or radiators.
Excessive heat could damage the internal components.
• Unit should be positioned to be accessible for future upgrade, maintenance and troubleshooting and
where cables can be easily connected.
• Maintain a minimum of 25 mm (1 in.) clearance around the unit.
• Keep airflow around and through the vents of the unit clear of any obstruction.
• Do not put books or paper on the unit.
Wiring Guidelines
These guidelines apply for any cable, supplied or not, used with a Mediatrix unit.
• Always use straight through cables.
• Cables must not pull or create a lateral stress on the connectors, i.e. they must be long enough.
• Cables must be installed in such a way not to present a trip hazard to personnel working in the vicinity of
the equipment.
• Keep cables away from:
— Sources of electrical noise such as radios, transmitters, and broadband amplifiers
— Power lines
— Fluorescent lighting fixtures
— Liquids or moisture
— Heat sources
Mediatrix Sentinel Characteristics
Parameter
Description
Dimensions
• Height: 4.4 cm (1.75 in)
• Width: 48.3 cm (19 in)
• Depth: 36.5 cm (14.4 in)