Model M - Mediatrix S7 Series and Mediatrix S7 LP Series
9
Requirements
Location Requirements
To avoid premature aging of the unit, insure user security and facilitate access, upgrades and
maintenance, the following guidelines must be followed.
•
Install the Mediatrix unit:
•
on a standard 48.26 cm (19 in.) equipment rack
•
on a flat surface (desk, table, etc.)
•
Install the Mediatrix unit in a well-ventilated location where it will not be exposed to high
temperatures or humidity.
•
Storage temperature: -20ºC to +70ºC
•
Operating temperature: 0ºC to +40ºC
Caution:
If the unit is installed in a closed environment or on a multi-unit rack, the
ambient temperature of the environment next to the Media5 unit may become greater
than the maximum operating temperature recommended by Media5 for the use of its
units, i.e. 40ºC. The Mediatrix unit should never be used to temperatures greater than
the recommended maximum operating temperature. Any damage occurring in such
environmental conditions will void the warranty.
•
Humidity lower than 85% and non-condensing
•
Do not install the Mediatrix unit in a location exposed to direct sunlight or near stoves or
radiators. Excessive heat could damage the internal components.
•
Unit should be positioned to be accessible for future upgrade, maintenance and
troubleshooting and where cables can be easily connected.
•
Maintain a minimum of 25 mm (1 in.) clearance in front, in the back, on top, under (for rack
mounted units), and on the sides of the unit.
•
Keep airflow around and through the vents of the unit clear of any obstruction.
•
Do not put books or paper on the unit.
Wiring Guidelines
These guidelines apply for any cable, supplied or not, used with a Mediatrix unit.
•
Always use straight through cables.
•
Cables must not pull or create a lateral stress on the connectors, i.e. they must be long enough.
media5corp.com