Model M - Mediatrix S7 Series and Mediatrix S7 LP Series
31
6)
Click
Apply
.
Important
:
Make sure to reconfigure at least the user's authentication and firewall rules (if
applicable), otherwise it may leave the unit unsecure.
Result
The unit will be reachable either on the new configured static IP address or on the DHCP .
Factory Reset
The Factory reset reverts the Mediatrix unit back to its default factory settings.
It deletes the persistent configuration parameters of the unit, including:
•
User files stored in the File service
•
Certificates, except for factory installed ones
•
Log files of the File service
The Factory reset should be performed with the Mediatrix unit connected to a network with access
to a DHCP server. If the unit cannot find a DHCP server, it will sent requests indefinitely. A Factory
Reset can be triggered either:
•
Directly on the unit. Refer to
(p.31).
•
Via the web interface of the Mediatrix unit (
Management
/
Firmware Upgrade
).
•
Via the Command Line Interface of the Mediatrix unit by using the
fpu.defaultsetting
parameter.
Performing a Factory Reset
Information
The Factory reset alters any persistent configuration data of the Mediatrix unit.
Steps
1)
Insert a small, unbent paper clip into the hole of the
Reset/Default
button, located on the
Mediatrix unit.
Note:
Do not release the
Reset/Default
button before the LEDs stop blinking and are steadily ON.
This can last from 12 to 16 seconds. If you leave the inserted pin longer, no action will be taken which
is useful if you accidentally pushed the button and do not need any action to be applied.
2)
Release the paper clip.