background image

Model M - Mediatrix S7 Series and Mediatrix S7 LP Series

19

You must use an IPv4 Network.

Make sure that your network connection is working.

Steps

1)

Make sure an adequate earth ground connection has been made between the grounding

screw on the back of the Mediatrix unit and an appropriate grounding point in your site.

Warning

 Adequate earth grounding connection of the Mediatrix unit is mandatory to avoid

any damage or injuries.

2)

Wear an ESD wrist strap, ensuring it makes good contact with your bare skin.

3)

Attach the ESD wrist strap end to an earth ground (grounding screw on the back on the

Mediatrix unit or unpainted bare metal spot of a grounded equipment rack).

4)

Make sure the unit's power switch is OFF.

5)

Make sure the circuit breakers of power sources used to power the Mediatrix unit are OFF.

6)

Make sure the provided AC Power Cord is connected into the POWER connector located on

the back of the Mediatrix unit and in an appropriate AC electrical outlet.

7)

Connect  a  10/100/1000  BaseT  Ethernet  RJ-45  cable  into  the  Ethernet  connector  of  the

Mediatrix unit.

8)

Connect the other end of the cable into your PC.

9)

Validate the installation.

10)

Turn ON the power sources that are used to power the Mediatrix unit at the circuit breaker.

Note: 

 When the unit is brought from a cold to a warm environment, condensation, that might be

harmful to the unit, may occur. If this is the case, wait one hour before connecting the power cord.

11)

Turn On the power switch of the Mediatrix.

media5corp.com

Содержание M - Sentinel 100

Страница 1: ...Model M Mediatrix S7 Series and Mediatrix S7 LP Series Hardware Installation Guide DGW 48 4 2631 2022 02 02...

Страница 2: ...ements 9 Wiring Guidelines 9 Mediatrix S7 Characteristics 10 Getting Started 11 Installation Check List 11 Package Check List 12 Cleaning Instructions 12 Mounting Tools and Equipment 12 Connectors and...

Страница 3: ...6 Partial Reset 27 Factory Reset 31 Standards Compliance and Disclaimers 33 Supported Standards 33 Federal Communications Commission FCC Disclaimer 35 Innovation Science and Economic Development Canad...

Страница 4: ...onnect its cables during periods of lightning Danger Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning Danger Do...

Страница 5: ...on connection may result in a safety hazard and or defective operation and or equipment damage Exposed plant means where any portion of the circuit is subject to accidental contact with electric light...

Страница 6: ...s units i e 40 C The Mediatrix unit should never be used to temperatures greater than the recommended maximum operating temperature Any damage occurring in such environmental conditions will void the...

Страница 7: ...m varoitusmerkki merkitsee vaaraa Olet tilanteessa joka voi johtaa ruumiinvammaan Ennen kuin ty skentelet mink n laitteiston parissa ota selv s hk kytkent ihin liittyvist vaaroista ja tavanomaisista...

Страница 8: ...familiarize se com os perigos relacionados com circuitos el ctricos e com quaisquer pr ticas comuns que possam prevenir poss veis acidentes Aviso Este s mbolo de aviso significa peligro Existe riesgo...

Страница 9: ...ix unit should never be used to temperatures greater than the recommended maximum operating temperature Any damage occurring in such environmental conditions will void the warranty Humidity lower than...

Страница 10: ...p cables away from Sources of electrical noise such as radios transmitters and broadband amplifiers Power lines Fluorescent lighting fixtures Liquids or moisture Heat sources Mediatrix S7 Characterist...

Страница 11: ...Voltage Installation site pre power check completed Mounting tools and equipment available Additional equipment available Mediatrix unit received Regulatory compliance and safety information received...

Страница 12: ...rgent wring well and then wipe off Use a dry cloth to dry the surface Mounting Tools and Equipment Tools Screwdriver as required for attaching brackets to rack ESD wrist strap Earth ground cable Warni...

Страница 13: ...LP Series 13 Connectors and Indicators Note The Mediatrix S7 is highly customisable in the sense that it may have one or several types of ports or none Therefore the following image may not exactly r...

Страница 14: ...nabled and at least one line is disabled operational state OFF Lines idled and unlocked Yellow steady ON Lines in use and unlocked 3 In Use Yellow blinking yellow 1 cycle per second 50 duty Locked Gre...

Страница 15: ...DM synchronisation pulse output 7 FXS card with 4 FXS ports 4 x RJ 11 connectors to attach a conventional telephone or G3 fax machine 8 ETH1 A 10 100 1000 BaseT Ethernet RJ 45 connector for access to...

Страница 16: ...his procedure you must first read and understand the Safety Recommendations listed in this document Note Note or take a picture of your unit s serial number before starting the installation and place...

Страница 17: ...Information Note To prevent damage to the Mediatrix unit make sure to connect the cables to their proper location on the Mediatrix unit Steps 1 Wear an ESD wrist strap ensuring it makes good contact w...

Страница 18: ...into the POWER connector located on the back of the Mediatrix unit and in an appropriate AC electrical outlet 7 Connect a 10 100 1000 BaseT Ethernet RJ 45 cable into the ETH1 connector of the Mediatri...

Страница 19: ...rounded equipment rack 4 Make sure the unit s power switch is OFF 5 Make sure the circuit breakers of power sources used to power the Mediatrix unit are OFF 6 Make sure the provided AC Power Cord is c...

Страница 20: ...the Ethernet port commonly used to be connected to the Local Area Network LAN i e ETH2 on most devices use the 192 168 0 10 IP address If your Mediatrix unit is configured to use a DHCP server with IP...

Страница 21: ...e length is 2 km Note The Mediatrix S7 LP supports longer FXS cables up to 2 km and offers an integrated secondary lightning protection whereas the regular Mediatrix S7 does not support these features...

Страница 22: ...detection meaning that they adapt to the type of cables connected to them The Auto MDI MDIX feature only works when the unit are configured in auto detect mode which is the default mode Pin Name Descr...

Страница 23: ...d Mediatrix S7 LP Series 23 LED Name Description A Speed OFF 10 Mbps Green 100 Mbps Yellow 1000 Mbps B Link activity Green blinking variable rate Network traffic Green steady On No network traffic OFF...

Страница 24: ...er Before you start Warning Make sure your unit is powered off Steps 1 Flip the unit The serial number is located underneath the unit Caution Use with internal Ethernet cable only Warning Make sure yo...

Страница 25: ...ivated Unable to contact the unit via SNMP SNMP service not activated Credentials do not grant access Unable to make calls although cards appear in the Management Interface Hour and date are not synch...

Страница 26: ...lt button is a switch that can be used to perform a partial or factory reset while the unit is running In other words the Reset Default button can be used to Cancel an action that was started Revert t...

Страница 27: ...art up of the Mediatrix unit or on a unit already in use where the configuration was modified in such a way that the user can no longer access the system by the Web page or otherwise In both cases the...

Страница 28: ...the Rescue Network Interface to use the link as the default value used by the Uplink Network Interface set the IP address to 192 168 0 1 and the Network Mask to 255 255 255 0 set the IPv6 link local a...

Страница 29: ...sAaaType table Each service will be configured to use Local authentication and no accounting mechanism EnableTelnet Disable TelnetPort 23 EnableSsh Enable SshPort 22 CLI InactivityTimeOut 15 HOC Manag...

Страница 30: ...ing the Management Interface Several parameters and services are modified refer to Partial Reset Do not forget to perform the Disabling the Rescue Interface step Disabling the Rescue Interface Informa...

Страница 31: ...ver If the unit cannot find a DHCP server it will sent requests indefinitely A Factory Reset can be triggered either Directly on the unit Refer to Performing a Factory Reset p 31 Via the web interface...

Страница 32: ...t All configuration parameters are reset to their default value The unit can then be contacted via its WAN interface DHCP provided IP address ETH1 or WAN on the 4102S or via its LAN interface default...

Страница 33: ...P Series 33 Standards Compliance and Disclaimers Supported Standards Note The standards compliance of the Mediatrix units are printed on the same sticker as the product serial number Refer to Locating...

Страница 34: ...y standards UL 60950 1 2nd Edition 2014 10 14 CAN CSA C22 2 No 60950 1 07 2nd Edition 2014 10 IEC 60950 1 2005 2nd Edition Am1 2009 Am2 2012 with all national deviations EN 60950 1 2006 A1 2010 A11 20...

Страница 35: ...y to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into...

Страница 36: ...le essential requirements of Directives 2014 30 EC and 2014 35 EC European parliament EMC and LVD directives is given Any unauthorized modification of the product voids this declaration For a copy of...

Страница 37: ...M Mediatrix S7 Series and Mediatrix S7 LP Series 37 Other Disclaimers Altitude of Operation Use only at altitudes no more than 2000 m above sea level Only use in non tropical climate regions media5cor...

Страница 38: ...M unit the SKU number is composed of 24 digits each having a specific meaning Letter Number Description Possible Values A Product family M G7 Series S7 Series S7 LP Series and Sentinel 100 B CPU 3 Ar...

Страница 39: ...China Y No power cord F Power supply 6 Single 65W PSU 120 240 Vac G Reserved field Software options 0 reserved 2 S7 Series and S7 LP Series H H H SBC sessions Survivability users 000 to 999 for senti...

Страница 40: ...x 1 TBD Custom SW profile Contact Media5 sales J SLA Support options 0 No SLA included in SKU must be separate line on PO 1 1 year SBC SLA support 5 5 year SBC SLA support K K SW license Software opti...

Страница 41: ...card 8 4BRI card 9 reserved A reserved B 4FXS Bypass card contact media5 sales C 2FXS Bypass card contact media5 sales K 2FXS LP card contact media5 sales L 4FXS LP card M 2FXS LP bypass card contact...

Страница 42: ...ehold waste at the end of its working life For appropriate disposal and recycling instructions contact your local Media5 Corporation provider The Waste of Electrical and Electronic Equipment WEEE Dire...

Страница 43: ...ins These documents are created to facilitate the configuration of a specific technical action such as performing a firmware upgrade Hardware installation guide They provide the detailed procedure on...

Страница 44: ...o the Intellectual Property of the document and the technology and know how that it includes and represents This publication cannot be reproduced neither in whole nor in part in any form whatsoever wi...

Страница 45: ......

Отзывы: