Model M - Mediatrix S7 Series and Mediatrix S7 LP Series
16
Installing The Mediatrix Unit
Before you start
Warning
:
When installing or replacing the Mediatrix unit, the earth ground connection
between the grounding screw on the back of the Mediatrix unit and an appropriate grounding
point in your site must always be made first and disconnected last. This is mandatory to avoid
any damage or injuries, even if the Mediatrix unit is installed in a grounded equipment rack.
Warning
:
The earth ground cable should be the same size (18 AWG minimum) as the earth
cable of the provided power cord. Otherwise, make sure the earth ground cable meets the
standards and requirements of your local electrical code. The type of the cable is likely to
have VW-1 or RT1 markings on the cable.
Warning
:
The earth ground cable must be firmly and securely connected to the grounding
screw on the back of the Mediatrix unit and an appropriate grounding point in your site: the
earth ground cable must remain tightly secured at all times during service and installation.
Warning
:
Before performing this procedure, you must first read and understand the Safety
Recommendations listed in this document.
Note:
Note or take a picture of your unit's serial number before starting the installation, and
place the card stickers of the cards not factory installed. Refer to
Locating the Product Serial Number
(p.24).
Steps
1)
Install the unit on a flat surface or in an equipment rack. Refer to
(p.17).
Caution:
If the unit is installed in a closed environment or on a multi-unit rack, the ambient
temperature of the environment next to the Media5 unit may become greater than the
maximum operating temperature recommended by Media5 for the use of its units, i.e. 40ºC.
The Mediatrix unit should never be used to temperatures greater than the recommended
maximum operating temperature. Any damage occurring in such environmental conditions
will void the warranty.
2)
Connect the Telephony Interface Cables. Refer to
Connecting the Telephony Cables
(p.17).
Caution:
To prevent damage to the Mediatrix unit, make sure to connect the cables to their
proper location on the Mediatrix unit.
3)
Connect the Ethernet Cables. Refer to:
a)
Connecting the Mediatrix Unit Using a DHCP Server
(p.17)
b)
Connecting the Mediatrix Unit Using a Static IP Address
(p.18)