background image

Questions?

  Visit 

www.medela.com

 or call us at 

1-800-435-8316.

9

8

4. Wash – 

Before first use and after each use*

Breastpump kits are a 

personal care item intended 

for use by a single user only 

and should not be shared 

between users.

Warning

You may also wash your kit parts 
by following the instructions on the 
Quick Clean

 Breastmilk Removal 

Soap bottle. (sold separately)

Supplies needed:

• 

Mild dish soap

• Clean dish towel or soft 

brush

• Clean sink or bowl
• Drinking-quality water

Parts to wash:

• 

Breastshields

• Breastmilk bottles/

containers

• Lids
•  Valves
• Connectors
• Membranes

 5

Note

Store the pump kit in a clean bag/container until 

next use.

 

•  Place parts on a clean surface 

and/or towel.

•  Allow all parts to air dry.
•  Store dry parts in a clean, cool 

place when not in use. Do NOT 
store wet or damp parts.

Rinse all separated parts that 
came in contact with breast and 
breastmilk in cool water in order 
to remove breastmilk residue.

•  Soak all separated parts in warm 

soapy water for 5 minutes.

•  Wash each part with a clean dish-

cloth or soft brush.

•  Rinse all separated parts with clear 

water.

Wash in sink

Separate and wash all parts that come in 

contact with breastmilk immediately after 

use to avoid dry up of breastmilk residue and 

prevent growth of bacteria.

Caution

Only use drinking-quality tap or bottled 
water for cleaning.

Caution

 2

 3

Note

If the individual components of the pump  

kit are cleaned in a dish washer, parts may 

be discolored by food pigments. This will not 

impact part function.

Wash in dishwasher

 4

•  Wash all separated parts on top 

rack of dishwasher.

•  Allow all breastpump parts to air 

dry in a clean area.

•  Store dry parts in a clean, cool 

place when not in use.

 1

• Separate parts for washing.

Note

• Wash breastpump kit parts after each use.

•  Take care not to damage parts of the pump 

kit during cleaning.

•  It is not necessary to wash tubing, 

membrane cap or protective membrane 

prior to fi rst use.

•  Only wash tubing if condensation or 

milk is present.

OR

Note

* Sterile kits are ready to use and 

do not require washing prior to 

fi rst use.

Содержание symphon

Страница 1: ...for double or single pumping para usarse con extractores de leche symphony para extracci n doble o simple made without made made without Not made with natural rubber latex or DEHP EN instructions ES i...

Страница 2: ...ospital grade electric breastpump that includes 2 Phase Expression technology and is capable of single and double pumping IMPORTANT Plastic bottles and component parts become brittle when frozen and m...

Страница 3: ...emove breastshield from your breast If pumping is uncomfortable or causing pain turn the unit off break the seal between the breast and the breastshield with your finger and remove the breastshield fr...

Страница 4: ...the battery 12 hours uninterrupted 2 Separate all parts 3 Clean see instructions Wash section 4 pages 8 9 Sanitize section 5 pages 10 11 3 Cleaning Overview Note Sterile kits are ready to use and do...

Страница 5: ...ue Soak all separated parts in warm soapy water for 5 minutes Wash each part with a clean dish cloth or soft brush Rinse all separated parts with clear water Wash in sink Separate and wash all parts t...

Страница 6: ...l place when not in use Do NOT store wet or damp parts Fill a pot with enough water to cover all parts Bring water to a boil Place parts in boiling water for 10 minutes Note Sanitize breastpump kit pa...

Страница 7: ...stpump Supplies needed Mild dish soap Clean dish towel Clean sink or bowl Drinking quality water Damp not wet cloth Parts needed Tubing Symphony pump Membrane cap Protective membrane Note Only wash tu...

Страница 8: ...w valve until membrane lies flat Push the breastshield onto the connector Screw connector onto the bottle container Insert the tubing into the corresponding opening in the connector Place the protecti...

Страница 9: ...e Symphony and lift the handle Center breastshields over your nipples and start pumping Caution pushing shields too firmly onto breasts may affect milk flow 10 14 11 15 Position the membrane cap firml...

Страница 10: ...ing the right size PersonalFit TM breastshield 1 Determine the size you re currently using If you re not sure look for the size embossed on your breastshield see picture 24 mm breastshields are provid...

Страница 11: ...the breastshield forms a complete seal around the breast Other Checks Inspect the following to check for damage and secure connections Secure tubing adapter to the breastshield connector Test vacuum I...

Страница 12: ...ilk not being drained from a specific duct The area becomes clogged up and milk is then prevented from flowing Mastitis It often follows engorgement but can occur suddenly The initial symptoms are sim...

Страница 13: ...ncia identifica todas las instrucciones que son importantes para la seguridad La inobservancia de estas instrucciones puede provocar lesiones o da os al extractor de leche Cuando los s mbolos de adver...

Страница 14: ...l pecho mientras est bombeando Apague el extractor de leche y despegue con el dedo el sello formado entre el pecho y el embudo luego retire el embudo del pecho Si el bombeo es molesto o provoca dolor...

Страница 15: ...ea las instrucciones Lavado secci n 4 p ginas 30 31 Esterilizaci n secci n 5 p ginas 32 33 3 Vistazo general de la limpieza Nota Los juegos est riles est n listos para usarse y no requieren de lavado...

Страница 16: ...arado en agua jabonosa durante 5 minutos Lave cada parte con un pa o limpio o con un cepillo suave Enjuague todas las partes por separado con agua limpia Lave en el lavabo Separe y lave todas las part...

Страница 17: ...uarde partes h medas o con agua Llene un recipiente con la cantidad suficiente de agua para cubrir todas las partes Hierva el agua Coloque las partes en agua hirviendo por 10 minutos Nota Esterilice l...

Страница 18: ...atos Toalla para platos limpia Fregadero o recipiente limpio Agua potable Trapo h medo no mojado Partes que necesita Tubo Extractor Symphony Tapa de la membrana Membrana protectora Nota S lo lave si h...

Страница 19: ...en la v lvula amarilla hasta que la membrana est plana Empuje el embudo en el conector Atornille el conector en la botella recipiente Inserte el tubo en la abertura correspondiente del conector Coloqu...

Страница 20: ...del extractor Symphony y levante la manija Centre los embudos sobre sus pezones y comience a bombear Precauci n empujar los embudos muy firmemente sobre los pechos puede afectar el flujo de leche 10 1...

Страница 21: ...a figura Los extractores Medela incluyen embudos de 24 mm 2 Durante la extracci n compare la posici n del pez n con la de las im genes a continuaci n a modo de gu a El embudo es demasiado grande prueb...

Страница 22: ...forme un sello total alrededor del pecho Otras comprobaciones Inspeccione lo siguiente para comprobar si hay da os y que las conexiones est n firmes Asegure el adaptador del tubo al conector del embu...

Страница 23: ...he no fluye desde un conducto espec fico El rea se obstruye e impide el flujo de la leche Mastitis Se produce a menudo despu s de una congesti n mamaria pero tambi n puede ocurrir repentinamente Los s...

Страница 24: ......

Страница 25: ...rcas comerciales registradas de Medela Holding AG 1 Choice of Hospitals and Mothers PersonalFit Quick Clean Tender Care y Micro Steam son marcas comerciales de Medela Inc 1908213 C 0315 2015 Medela In...

Отзывы: