© MEDC 2002

12/03

3.4 DELETING A RECORDING

To delete a recording press the RED record button once.

4.

MAINTENANCE

During the working life of the unit, it should require little or no maintenance. GRP
will resist attack by most acids/alkalis and chemicals and is as resistant to
concentrated acids and alkalis as most metal products. However, the unit is not
suitable for use in environments containing carbon disulphide.

If abnormal or unusual environmental conditions occur due to plant damage or
accident etc., then visual inspection is recommended. If the unit requires cleaning,
then only clean exterior with a damp cloth to avoid electro-static charge build up.
Painting and other surface finishes, other than those applied by the manufacturer,
are not permitted.

If a fault should occur, then the unit should be returned to MEDC for repair/
replacement.

If you acquired a significant quantity of units, then it is recommended that spares
are also made available. If spare parts are required, these should only be
supplied by MEDC.

5.

CERTIFICATION/APPROVALS

Certified to EN50014:1997, EN50018:1994 & EN50019:1994

ATEX Certificate No. BAS00ATEX2097X (EExd IIC)

BAS00ATEX2098X (EExde IIC)

GENERAL ARRANGEMENT

Содержание DB3V

Страница 1: ...been taken to ensure the accuracy of our technical manual We do not however accept responsibility for damage loss or expense resulting from any error or omission We reserve the right to make alterati...

Страница 2: ...should be referred to e g IEE Wiring Regulations and the National Electrical Code in North America Additional national and or local requirements may apply Ensure that all nuts bolts and fixings are se...

Страница 3: ...t least 5mm EExd EExde units Cable termination should be in accordance with specifications applying to the required application MEDC recommends that all cables and cores should be correctly identified...

Страница 4: ...number two of SW1 back to the OFF position To re record the message press and hold the Red record button and playback the audio source as before The previous message will be recorded over 3 2 NORMAL...

Страница 5: ...ccident etc then visual inspection is recommended If the unit requires cleaning then only clean exterior with a damp cloth to avoid electro static charge build up Painting and other surface finishes o...

Страница 6: ...to 45 C T5 DB3LE 55 C to 55 C T5 The ATEX certificate and the product carry the ATEX group and category marking II 2 GD Where signifies compliance with ATEX II signifies suitability for use in surface...

Страница 7: ...MEDC 2002 12 03...

Страница 8: ...liery Road Pinxton Nottingham NG16 6JF UK Tel 44 0 1773 864100 Fax 44 0 1773 582800 Sales Enq Fax 44 0 1773 582830 Sales Orders Fax 44 0 1773 582832 MEDC Stock No E mail sales medc com Web www medc co...

Отзывы: