Cable Termination

CAUTION: Before removing the cover assembly, ensure that the power to the
unit is isolated.

Unscrew the 6 off M5 cover screws (EExd version) or 2 off M5 cover screws
(EExde version) and remove cover assembly to gain access to the terminals.

EExde units only:

1. Not more than one single or multiple strand lead shall be connected into

either side of any terminal, unless multiple conductors have been joined in a
suitable manner, e.g. two conductors into a single insulated crimped boot
lace ferrule.

2. Leads connected to the terminals shall be insulated for at least 275V and this

insulation shall extend to within 1mm of the metal of the terminal throat.

3. All terminal screws, used and unused, shall be tightened down.

4. Minimum creepage and clearance distances between the terminals and

adjacent conductive parts (including cable entry devices) must be at least 5mm.

EExd & EExde units

Cable termination should be in accordance with specifications applying to the
required application. MEDC recommends that all cables and cores should be
correctly identified. Please refer to the wiring diagram provided with the product.

Ensure that only the correct listed or certified cable glands are used and that the
assembly is shrouded and correctly earthed.

All cable glands should be of an equivalent NEMA/IP rating to that of the unit
and integrated with the unit such that this rating is maintained.

The internal earth terminal, where fitted, must be used for the equipment
grounding connection and any external terminal is for a supplementary bonding
connection where local codes or authorities permit or require such a connection.

Once termination is complete, replace cover assembly. Position the 6 off M5
cover screws (EExd version) or 2 off M5 cover screws (EExde version) into the
holes in the cover and tighten evenly.

3.

OPERATION

The sounder is available in the DC voltage input version only.

The absolute input voltage range is 11.0V to 58.0V

Содержание DB3V

Страница 1: ...been taken to ensure the accuracy of our technical manual We do not however accept responsibility for damage loss or expense resulting from any error or omission We reserve the right to make alterati...

Страница 2: ...should be referred to e g IEE Wiring Regulations and the National Electrical Code in North America Additional national and or local requirements may apply Ensure that all nuts bolts and fixings are se...

Страница 3: ...t least 5mm EExd EExde units Cable termination should be in accordance with specifications applying to the required application MEDC recommends that all cables and cores should be correctly identified...

Страница 4: ...number two of SW1 back to the OFF position To re record the message press and hold the Red record button and playback the audio source as before The previous message will be recorded over 3 2 NORMAL...

Страница 5: ...ccident etc then visual inspection is recommended If the unit requires cleaning then only clean exterior with a damp cloth to avoid electro static charge build up Painting and other surface finishes o...

Страница 6: ...to 45 C T5 DB3LE 55 C to 55 C T5 The ATEX certificate and the product carry the ATEX group and category marking II 2 GD Where signifies compliance with ATEX II signifies suitability for use in surface...

Страница 7: ...MEDC 2002 12 03...

Страница 8: ...liery Road Pinxton Nottingham NG16 6JF UK Tel 44 0 1773 864100 Fax 44 0 1773 582800 Sales Enq Fax 44 0 1773 582830 Sales Orders Fax 44 0 1773 582832 MEDC Stock No E mail sales medc com Web www medc co...

Отзывы: