Med-link Electronics AM-806VB Скачать руководство пользователя страница 5

方法

3

4

Bluetooth 

Dimension and Weighting

Operating Temperature  

Atmospheric pressure 

for transportation and storage

41°F

104°F (5

℃~

40

℃)

86kPa

106kPa

Protection Against Liquids

Weight 

Size

IPX2, Vertically falling drops shall have no harmful effects when 
the enclosure is tilted at any angle up to 15°on either side of the
vertical; IPX1, Vertically falling drops shall have no harmful effects

80

.

0*38

.

0*40

.

0mm

60g 

Transmitting frequency 

Modulation Type 

2

.

4G

GFSK

Environment

Transportation and 

Storage Temperature 

14°F

104°F (-10

℃~

40

℃)

Transportation and 

Storage Humidity

0%

80% No condensation

Classification

Frequency characteristic 

Radiation power 

FHSS

0dbm

This device is calibrated to show functional oxygen saturation. 
The displayed value of this device is averaged, and there is a certain delay relative to the real data. 
The pulse wave displayed on the device is normalized. 
The pulse amplitude intensity represents the relative intensity of the tester's arterial pulsation, and a 
weak pulse amplitude intensity value can cause erroneous readings. 
To  ensure  the  accuracy  of  temperature  measurement,  please  use  the  reusable  body  cavity 
temperature probe for animal to measure the same position for at least 90 seconds.  
Medical high frequency signals or defibrillator interference can cause erroneous readings.
External ambient light interference will affect the accuracy of blood oxygen.
The movement interference of the animal subject will affect measurement accuracy. 
This  product  does  not  have  an  alarm  function,  but  it  provides  a  settable  prompt  function  when  the 
value is beyond the range. Please pay attention to the related information. 

1.5

 

Warnings

!

1.6  Symbols and signs

SpO2, Pulse Rate, Temperature, Pulse Waveform, Bar Graph and Low-Battery Indicator

Display Parameters

NON

STERILE

-10

40

80%

0%

Warning

Non-sterile Packaging

Refer to instructions 
for use

DO NOT THROW 
AWAY Intended for 
multiple use

Temperature limits 
for transportation 
and storage 

Humidity limit for 
transportation and 
storage

Atmospheric pressure 
for transportation 
and storage

Electronic products
Environment-friendly 
use period

Date of manufacture

Batch Code

Protected against 
vertically falling water 
drops when enclosure
tilted up to 15°

Compliance with 
WEEE Standard

No SpO2 Alarm

CE Mark: conforms to essential requirements of the Medical Device 
Directive 93/42/EEC. 0123 is Notified Body Number

LOT

Содержание AM-806VB

Страница 1: ...Fax 86 755 61120055 Email kefu medxing com Website www medxing com Shenzhen Med link Electronics Tech Co Ltd AM 806VB REV A 1 Revision date October 24 2019 Veterinary Temp pulse Oximeter Instructions...

Страница 2: ...t sites that are not well perfused To prevent this situation please check application sites of animal subject frequently If the initial skin temperature does not exceed 35 C the operation of the senso...

Страница 3: ...ing inspection 07 1 12 Packaging 07 Chapter II Operation 08 2 1 Installation and confirmation 08 2 2 Operation and use 10 2 3 Security 11 2 4 Function settings 12 2 5 Menu Settings 13 2 6 List of appl...

Страница 4: ...2 Display 7 Bar graph The Pulse Amplitude Indicator 3 Battery indicator 8 Display direction switch 4 Temperature Display 9 Accessory connector 5 Pulse Rate Display bpm 1 4 Technical Specifications Bat...

Страница 5: ...rement please use the reusable body cavity temperature probe for animal to measure the same position for at least 90 seconds Medical high frequency signals or defibrillator interference can cause erro...

Страница 6: ...the two wavelengths can be calculated thereby the oxygen saturation of the arterial blood can be accurately measured within the range of 70 100 obtaining the pleth waveform and the pulse rate value 1...

Страница 7: ...ease contact the Technical Service Department You can contact by Phone 86 755 61120085 Fax 86 755 61120055 Email user07 med linket com 1 11 Unpacking and Inspection 1 12 Included in the package Sectio...

Страница 8: ...ning properly or not Caution 2 2 General Operation Preparation 1 Please make sure that the host battery is fully charged If the battery is low please plug in the USB cable to charge 2 Press the power...

Страница 9: ...pressure cuff or intravenous injection Make sure the light source is from the internal transparent silica gel Any other light source may cause incorrect SpO2 measurement and venous pulsation Strong l...

Страница 10: ...completing the setting the interface will indicate OK Move the cursor to select Exit by short pressing the button and then long press the button to return to the testing interface Setting of SpO2 upp...

Страница 11: ...em of Exit to return to the testing interface Return to the testing interface Warning Uncomfortable or painful feeling may appear if using the device ceaselessly especially for animals with blood micr...

Страница 12: ...sound which can be turned off by turning off the Alm function Temperature value goes beyond the display range of the device The temperature measurement function is malfunctional If the Alm function is...

Страница 13: ...ng time please charge it at least once every 3 months to maintain the battery The best storage environment of the device is between room temperature 10 C and 40 C with humidity not higher than 80 Plea...

Страница 14: ...0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O indicates that the content of the toxic and hazardous substances in all homogeneous materials of the part is subject to the...

Страница 15: ......

Страница 16: ...stomer name Tel Address Product Name Product REFNO Purchase Date Cityof Purchase FailureDescription Product maintenance card This joint is reserved for customers with this card repair and return Custo...

Отзывы: