CRIMP DATA ANALYZER
CDA10
REV.01
85
6.6.3
HOW CRIMP FORCE MISMATCH IS CALCULATED
The figure below shows a reference curve (in red) and a superimposed force curve for comparison
(blue). In this example, the blue curve could be typically associated with a crimping error on
insulation.
The figure below shows the area that is non-corresponding, which is given by the difference
between the two curves.
The controller measures this area for each crimping cycle. The
algorithm does not take into account whether the error occurs above or below the reference curve,
but all errors are accumulated positively.
Содержание CDA10
Страница 2: ......
Страница 3: ......
Страница 11: ...CRIMP DATA ANALYZER CDA10 REV 01 9...
Страница 20: ...CRIMP DATA ANALYZER CDA10 REV 01 18...
Страница 22: ...CRIMP DATA ANALYZER CDA10 REV 01 20...
Страница 31: ...CRIMP DATA ANALYZER CDA10 REV 01 29...
Страница 33: ...CRIMP DATA ANALYZER CDA10 REV 01 31...
Страница 35: ...CRIMP DATA ANALYZER CDA10 REV 01 33 Installation on TT and P107 presses Installation on P040 and P080 presses...
Страница 36: ...CRIMP DATA ANALYZER CDA10 REV 01 34...
Страница 41: ...CRIMP DATA ANALYZER CDA10 REV 01 39...
Страница 43: ...CRIMP DATA ANALYZER CDA10 REV 01 41...
Страница 48: ...CRIMP DATA ANALYZER CDA10 REV 01 46...
Страница 50: ...CRIMP DATA ANALYZER CDA10 REV 01 48...
Страница 65: ...CRIMP DATA ANALYZER CDA10 REV 01 63...
Страница 66: ...CRIMP DATA ANALYZER CDA10 REV 01 64...
Страница 67: ...CRIMP DATA ANALYZER CDA10 REV 01 65...
Страница 69: ...CRIMP DATA ANALYZER CDA10 REV 01 67...
Страница 95: ...CRIMP DATA ANALYZER CDA10 REV 01 93...
Страница 99: ...CRIMP DATA ANALYZER CDA10 REV 01 97...
Страница 101: ...CRIMP DATA ANALYZER CDA10 REV 01 99...
Страница 113: ...CRIMP DATA ANALYZER CDA10 REV 01 111 MAINTENANCE LOG DATE OPERATOR DESCRIPTION OF INTERVENTION...
Страница 115: ...CRIMP DATA ANALYZER CDA10 REV 01 113...
Страница 117: ...CRIMP DATA ANALYZER CDA10 REV 01 115...
Страница 119: ...CRIMP DATA ANALYZER CDA10 REV 01 117 9 1 MACHINE LAYOUT...