Page 58
65-J Desel - Servce & Parts Manual
February 2021
Secton 17 - Calbraton Problems
F52:NOT CALIBRATED
This message is a catch-all code which indicates an improper calibration sequence or that one
of the phases of calibration was not completed. The skipped phase must be completed or the
calibration sequence must be passed through in proper sequence before this message will clear.
Re-start the calibration sequence and proceed through each sequence in the specified order.
A “Redo” prompt will appear before each sequence. Answer “NO” if there is no reason to repeat
or “YES” if the phase must be completed.
F60:BAD EXTENSION
Extension has not been calibrated or is faulty at the start of Load Calibration.
F61:BAD EXTENSION
Extension is out of range at the start of Extension Calibration.
F62:BAD EXTENSION
Extension is out of range at the start of Extension Calibration.
F63:BAD EXTENSION
Extension is out of range at the end of Extension Calibration.
F64:BAD EXTENSION
Problem at the end of Extension Calibration -- not enough difference between start and end
points
F65:BAD EXTENSION
Use Boom Extend function to calibrate extension.
•
•
•
•
•
•
•
•