Page 55
65-J Desel - Servce & Parts Manual
February 2021
Secton 17 - Calbraton Problems
F10:BAD HEIGHT1
F10:BAD HEIGHT2
This message is given if the height sensor output (P8-2) is out of range at the end of the
DYNAMIC lift. The height sensor output must be between 1.0V and 4.0V. Check DIAGNOSTICS/
SENSORS to see the output. A reading of 0V or 5V is probably due to a wiring problem.
F11:NOT UP
F11:NOT DOWN
This message occurs at the start of the DYNAMIC lift if the operator selects a function other than
UP.
F12:TOO MANY
This message occurs if the DYNAMIC lift takes too long.
This message could occur if the UP switch was not released at the end of the dynamic lift.
F13:LOW HEIGHT RANGE
This message occurs at the end of the DYNAMIC lift if the height sensor output did not change
sufficiently to give a reasonably accurate platform height estimate. DIAGNOSTICS / ANALOGS
can be used to check the height sensor output (P8-2) when the platform is fully lowered and fully
raised; a difference of at least 1V is to be expected.
This message could occur if the UP switch was accidentally opened too early (when the platform
is not fully raised).
F14:BAD HEIGHT1
This message occurs if EZfit#1 output is out of range during the DYNAMIC lift. The height sensor
output must be between 1.0V and 4.0V. Check DIAGNOSTICS / SENSORS to see the output. A
reading of 0V or 5V is probably due to a wiring problem.
F15:CHECK ELEV
This message is given if the elevation switch (P7-5) is open when the platform has been fully
lowered after the DYNAMIC lift.
This message would occur if the DOWN switch was accidentally opened before the platform was
fully lowered.
If the platform is fully lowered, check the elevation switch. Check that the boom is fully retracted.
F16:LOW ELEV������OPEN
This message is given if the elevation switch (P7-5) opened during lift at too low of a height
(below 5%). Check CALIBRATIONS / HEIGHT CALS. The “ElevUp” value shows the recorded
height where the switch opened. Check that the boom is fully retracted.
F17:HIGH ELEV������OPEN
This message is given if the elevation switch (P7-5) opened during lift at a too high height
(above 25%).
Check CALIBRATIONS / HEIGHT CALS; the “ElevUp” value shows the recorded height where
the switch opened. Check that the boom is fully retracted.
F18:LOW ELEV������CLOSE
This message is given if the elevation switch (P7-5) closed during lower at a too low height
(below 5%).
Check CALIBRATIONS / HEIGHT CALS; the “ElevDown” value shows the recorded height
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Содержание 65-J Diesel
Страница 1: ...Part 95105 February 2021 Serial Number Range 14800000 Up Service Parts Manual 65 J Diesel ART_4883 ...
Страница 223: ...Page 217 65 J Diesel Service Parts Manual February 2021 Notes ...
Страница 224: ...Page 218 65 J Diesel Service Parts Manual February 2021 Notes ...
Страница 225: ...Page 219 65 J Diesel Service Parts Manual February 2021 Notes ...