Page 109
65-J Desel - Servce & Parts Manual
February 2021
Secton 19 - Troubleshootng
FAULT: CHECK HEIGHT SENSORS!____________________ Flash Code 6/1
Voltage from Height sensors out of range, should be .5 volts to 4.5 volts
FAULT: CHECK PRESSURE SENSOR!___________________ Flash Code 6/2
Voltage from Pressure sensor out of range, should be .5 to 4.5 volts (Overload option only).
FAULT: CHECK ELEVATION SWITCH!___________________ Flash Code 6/3
Check for incorrect GP 400 part.
FAULT: LOW OIL PRESSURE!____________________ _ Flash Code 7/7
Engine Start was pushed but engine did not start or oil pressure switch did not close.
Engine Oil Pressure is low. Check oil level.
FAULT: SOME BIG BAD PROBLEM!_____________________ Flash Code 9/9
A failure happened that has no message associated with it. This should never occur.
•
•
•
•
•
•