93924 – September 2015
Page 17
60-J Diesel
Operating Instructions & Pre-Operation Function Tests
Starting Engine from Platform Controls
•
Lower Control Box:
Turn the Key Switch to PLATFORM.
•
Platform Control Box:
Move the Start/Stop switch UP to start. Release the switch
when the engine starts.
•
Cold Start:
Move and hold the Glow Switch up as indicated in the Preheat table.
• With the Glow switch held up, press and hold the Start/Stop switch UP until the
engine starts.
• Release both switches once the engine starts.
• To protect the starter motor, power will cut off to the starter circuit when the starter
motor has run continuously for 15 seconds without starting the engine. The Starter
Circuit Cutout indicator light will turn on at the Base Control panel and power to the
starter circuit will cut out for 30 seconds.
ART_4721
ART_4725
ART_4726
Preheat Table
Ambient Temperature
Preheat Time
Above 10°C
5 Seconds
10°C to –5°C
10 Seconds
Below –5°C
20 Seconds
20 Seconds = Limit of Continuous Use