Page 76
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 7 - Mechancal System
Floating Axle Lock Cylinders
There are two Floating Axle Lock Cylinders located at the front of the machine.
Remove
Raise and support the front end of machine.
Disconnect hydraulic hoses. Immediately cap and plug all openings to prevent contamination.
Remove the bolt and banjo pin that secures the pivot pin to the frame and remove the pivot pin.
Remove the bolt and banjo pin that secures the pivot pin to the floating axle and remove the
pivot pin.
Replace
Installation is reverse of removal. Apply one (1) drop of Loctite® to the bolts that secure clevis pins.
Bleed Procedure - 3084RT
Use this procedure for machine model 3084RT.
Start engine.
Loosen the bleed valve located on the top of the cylinder.
Watch as air escapes from valve.
Once a steady stream of fluid runs from the valve, tighten the valve.
Repeat on opposite side.
Bleed Procedure - 3084ES
Use this procedure for machine model 3084ES.
Loosen the bleed valve located on top of the cylinder
Drive the machine very slowly while watching as air escapes from the valve.
Once a steady stream of fluid runs from the valve, tighten the valve.
Repeat on opposite side.